CONNECTING THE LIQUID PROPANE CYLINDER:
To connect the Liquid Propane gas supply cylinder: The cylinder valve should be in the "OFF" position. If not, turn the
valve clockwise until it stops. Make sure the cylinder valve has the proper type-1 external male thread connections
per ANSI Z211.81. Make sure the burner valves are in the "OFF" position. Inspect the valve connections, port and
regulator assembly to the valve, and use your hand to tighten the nut clockwise until it stops. The use of a wrench
could damage the quick coupling nut and result in a hazardous situation, open the cylinder valve fully by turning the
valve anti-clockwise. Before lighting the appliance, use a soap and water solution to check all the connections for
leaks. If a leak is found, turn the cylinder valve "OFF" and do not use the appliance until a local Liquid Propane dealer
can make repairs.
OUTDOOR INSTALLATION GUIDE
This appliance shall only be used in an above-ground open-air situation with natural ventilation, without stagnant
areas, where gas leakage and products of combustion are rapidly dispersed by wind and natural convection.
This appliance
must not
be used indoors. Do not use your appliance in garages, porches, sheds, or other enclosed
areas. The appliance is not intended to be installed in or used on recreational vehicles (e.g., boats, trucks, and tents)
and should not be placed close to or under any surfaces that will burn or are sensitive to heat. Do not block/ obstruct
the flow of air and combustion around the appliance housing while in use.
Battery Installation:
Unscrew the pulse igniter cap to fit one new AA battery note the (+) and (–) marking and refit the cap.
KILN R Series - 2 Burner
Remove the battery compartment cover. Load a set of four new AA type batteries so that their plus (+) and minus (–)
ends are facing as indicated by the markings. Refit battery compartment cover.
WARNING:
1. Do not store a spare LP gas cylinder under or near this appliance.
2. Never fill the cylinder beyond 80 percent full.
3. If the information in items 1&2 is not followed exactly, a fire causing death or serious
injury may occur.
CAUTION: Place dust cap on cylinder valve outlet whenever the cylinder is not in use.
Only install the type of dust cap on the cylinder valve outlet that is provided with the
cylinder valve. Other types of caps or plugs may result in leakage of propane.