FOR PROPANE CYLINDER CONNECTION:
•
To achieve the optimum performance from your appliance, an approved gas cylinder/ bottle must be used. The
supplied hose and/or regulator must first be connected to the appliance inlet.
•
Do not connect a gas cylinder/ bottle to a appliance that is not secured in the supplied stand or on a stable raised
surface. The cylinder should be lower than the appliance, in a protected place on a stable surface.
•
Before connecting the gas supply, take care that all gas control knobs are in the off position. Once connected,
turn the regulator handle on to turn on the gas supply. Check all joints are secure.
NOTE: Only one gas cylinder should be stored on the stand at any one time.
LEAK TESTING
Make sure the gas control knob is Off and turn the cylinder valve On.
1.
2. Check for leaking joints by brushing with a solution of half-liquid detergent and half-water. If a leak is present,
bubbles will appear (or you may hear a hissing sound). Retightening connections can generally repair a leaking
joint. You must also check the gas hose and connection at the gas cylinder. If a leak cannot be resolved, do not
proceed and turn the gas cylinder/bottle valve off.
DO NOT USE NAKED FLAME FOR LOCATING GAS LEAKS.
IF A LEAK PERSISTS CALL AN AUTHORIZED GAS FITTER.
SPECIAL INSTRUCTIONS FOR THE USE OF REGULATOR AND PROPANE CYLINDER
GAS HOOK-UP: Only the pressure regulator and hose assembly supplied with the appliance should be used. Any
replacement pressure regulator and hose assembly must be specified by the appliance manufacturer. This appliance
is configured for Liquid Propane. Do not use a Natural Gas supply.
LIQUID PROPANE CYLINDER REQUIREMENTS: (The LP cylinder must be a 20-lb). A dented or rusty Liquid Propane
cylinder may be hazardous and should be checked by your supplier. Never use a cylinder with a damaged valve. The
Liquid Propane cylinder must be constructed and marked in accordance with the specifications for Liquid Propane
cylinders by the United States Department of Transportation (DOT) or the National Standard of Canada, CAN/
CSA-B339, Cylinders, Spheres and Tubes for Transportation of Dangerous Goods Commission. The 20-lb cylinder
must have a shut off valve terminating in a valve outlet specified, as applicable, for connection type QCC1 in the
standard for compressed gas cylinder valve outlet and inlet connection ANSI/CGA-V-1. Storage of an outdoor cooking
gas appliance indoor is permissible only if the cylinder is disconnected and removed from the outdoor cooking gas
appliance. The cylinder system must be arranged for vapor withdrawal. The cylinder must include a collar to protect
the cylinder valve. Manifold pressure: (operating) 11 inches water column (W.C.), (non-operating) 11.2 inches water
column (W.C.). The Liquid Propane cylinder must be fitted with an Overfill Protection Device (OPD). Remove the
plastic valve cover from the Liquid Propane cylinder is placed into the cart.
5