7. Trouble Shooting
Having trouble?
Noise is louder than specifications.
Nothing appears in the IR wireless remote controller display, the display is
faint, or signals are not received by the indoor unit unless the IR remote
controller is close. (*2)
The operation lamp near the receiver for the IR wireless remote controller
on the indoor unit is blinking. (*2)
*2: Only for IR wireless remote controller

8. Specifications

Model
Function
Power supply
Capacity
BTU/h
Input
kW
CMM
Airflow (Lo-Mid-Hi)
CFM
L/S
in. WG
Ext. static pressure
[Pa]
Noise level (Lo-Mid-Hi)
dB
Weight
kg [Ib]
Notes: 1. Rating conditions (cooling)
2. Rating conditions (heating)
3. The capacity is indicated the value when one indoor unit is connected to the outdoor unit.
4. Specifications subject to change without notice.
5. The external static pressure is set to 15 Pa at factory shipment.
Guaranteed operating range
Upper limit
Cooling
Lower limit
Upper limit
Heating
Lower limit
Notes: 1. Units should be installed by licensed electric contractor accordingly to local code requirement.
2. For outdoor units to be connected, refer to the Installation Manual that comes with the units.
3. Single outdoor unit (either PUY-A12,18NHA
PEA-A12AA4
Cooling
12,000
0.07
7-9-11
247-317-388
116-150-183
0.02-0.06-0.14-0.20
[5/15/35/50]
23-28-33
21 [48]
Indoor : 80 °F [26.7 °C] D.B., 67 °F [19.4 °C] W.B. Outdoor
Indoor : 70 °F [21.1 °C] D.B.
Indoor
90 °F [32 °C] D.B., 73 °F [23 °C] W.B.
66 °F [19 °C] D.B., 59 °F [15 °C] W.B.
83 °F [28 °C] D.B., –
63 °F [17 °C] D.B., –
or PUZ-A18NHA ) will be connected to each indoor unit.
(1)
Here is the solution. (Unit is operating normally.)
■ The indoor operation sound level is affected by the acoustics of the par-
ticular room as shown in the following table and will be higher than the
noise specification, which was measured in an echo-free room.
High sound-
absorbing rooms
Broadcasting
Location
studio, music
examples
room, etc.
Noise levels
3 to 7 dB
■ The batteries are low.
Replace the batteries and press the Reset button.
■ If nothing appears even after the batteries are replaced, make sure that
the batteries are installed in the correct directions (+, –).
■ The self diagnosis function has operated to protect the air conditioner.
■ Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
Heating
Cooling
~/N, 208/230V, 60Hz
22,000
0.09
: 95 °F [35 °C] D.B.
Outdoor
: 47 °F [8.3 °C] D.B., 43 °F [6.1 °C] W.B.
70 °F [21 °C] D.B., 59 °F [15 °C] W.B.
12 °F [-11 °C] D.B., 10 °F [-12 °C] W.B.
Low sound-
Normal rooms
absorbing rooms
Reception room,
Office, hotel
hotel lobby, etc.
room
6 to 10 dB
9 to 13 dB
PEA-A18AA4
Heating
23,200
0.07
12-15-18
423-529-635
200-250-300
0.02-0.06-0.14-0.20
[5/15/35/50]
30-34-38
27 [60]
Outdoor
115 °F [46 °C] D.B., –
23 °F [-5 °C] D.B., –
7