Operation
4.2.6 Starting up
Slide the ON-OFF switch
•
•
The battery charge level
•
The battery
charge level that is too low can result in serious injury and damage due to sudden dropping of
the lifted load!!!
The battery can be charged at any time without reducing the battery life.
•
If the holding force begins to decrease noticeably even though the battery is fully charged, check
•
the rubber foam seal for wear or damage. Do not attempt to lift a load with the unit until the rubber
foam seal has been replaced.
•
Position the device on the surface to be lifted.
•
To switch on the vacuum pump and trigger suction of the load, press the green button
the device at the handle for a few seconds with light force against the load to be lifted and the
suction process begins.
The load may only be lifted when the LED (indicator) lights up green.
•
If the suctioned load is to be released again, the red button
•
The suction process then immediately starts again. This can be interrupted by pressing the green
•
button
The indication of the measured value in the display
•
suction process) by pressing the button
psi).
The digital manometer
•
with slightly porous materials. If the display shows less than - 0.6 bar (- 8,7 psi), discard
load immediately!
58500014
to the ON position to switch on the unit.
①
should always be fully charged before each use. Wounding the unit with a battery
⑥
.
③
must be constantly in the operator's field of vision, especially
⑤
is shown directly in the display.
②
can be changed during operation (in the
⑤
(load WLL in kg or lbs // negative pressure in bar or
⑧
13 / 17
must be pressed.
④
. Press
③
GB