Télécharger Imprimer la page

BWT myPOOL MP-IHP 50 Mode D'emploi page 33

Publicité

Les langues disponibles

Les langues disponibles

For power supply: 230V 50Hz
Power Supply
230V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
The swimming pool heater must be earthed well.
3. Electric Wiring Diagram
Options for protecting devices and cable specification
MODEL
Rated Current
A
Breaker
Rated Residual
Action Current
mA
Fuse
A
2
Power Cord
(mm
2
Signal cable
(mm
Note: The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire
diameter must be increased. The signal cable can be extended to 50m at most.
4. Installation instruction and requirement
The heat pump must be installed by a professional team. The users are not qualified to
install by themselves, otherwise the heat pump might be damaged and risky for users'
safety.
Distribution Box
(Customer prepare)
Fuse
Breaker
MP-IHP 50
MP-IHP 62
8.0
30
8.0
)
3×1.5
)
3×0.5
※ Above data is subject to modification without notice.
Power Cord
MP-IHP 80
8.0
9.5
30
30
8.0
9.5
3×1.5
3×1.5
3×0.5
3×0.5
Swimming Pool Heat Pump Wiring Board
MP-IHP 96
MP-IHP 125
11.5
15.0
30
30
11.5
15.0
3×2.5
3×2.5
3×0.5
3×0.5
MP-IHP 165
20.5
30
20.5
3×4
3×0.5

Publicité