Vertical installation
2b
1
12
4
WARNING:
Disconnect all electrical power before starting
installation, maintenance, or service work.
Installations must only be carried out by
qualified personnel.
Plug connections have to be completely dry.
8
11
11
3
Examples are for
reference only.
12
INPUT POWER:
100-240V, 50/60Hz, 2.5A (Max)
The alarm relay fuse must be rated for the specific
application and of the HRC type, 5 x 20mm 250 VAC,
6.3A (Max)
This appliance incorporates an earth connection for
functional purposes only
Please note that some air conditioners are equip-
ped with components that generate high-frequency
electromagnetic field, such as an air purifier, which
may interfere with the digital water sensor. It is re-
commended to place the sensor as far as possible
from such a device and to check the operation of
the condensate pump once the air conditioner is
turned on.
Instruction manual Combi