AIR OUTLET IN A RECYCLING HOOD VERSION

• In case the components requested for the recycling functioning
have been removed earlier these have to be positioned again.
• Put the plastic tube onto the flange 7.
• Place the air outlet grid 8 on the air outlet. Make sure that the
position of the grid is correct.
• Make sure that charcoal filters have been placed inside the
hood.

ELECTRICAL CONNECTION

• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.