CAUTION! HOT WHILE IN OPER-
WARNING
ATION. DO NOT TOUCH. KEEP
CHILDREN, ANIMALS, CLOTHING AND COM-
BUSTIBLES AWAY FROM HEATER.
Keep this heater clear and free from all combustible
materials, gasoline, and other flammable vapors and
liquid.
Minimum Clearance From Combustibles
Sides
MH-16-TTC
3 ft.
MH-32-TTC
3 ft.
MH-360A-TTC
5 ft.
For installation on combustible flooring as a free
standing unit with the following minimum clearances
from combustible construction:
Top:
5 ft.
Front:
Rear:
3 ft. (5 ft.*)
*MH-360A-TTC only
For use with propane (LP)
WARNING
gas only.
DO NOT use any LP cylinder
WARNING
larger than 20 lbs.
It is the owner's responsibility to communicate
combustible clearances with others.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
ALWAYS provide adequate clearance for accessibility,
combustion and ventilation (air supply) while heater is
operating.
– Use heater in accordance with all local codes.
In the absence of local codes, refer to The
National Fuel Code, ANSI Z223.1.
RISK OF FIRE! ALWAYS ATTACH THE HEATER IN AN UPRIGHT VERTICAL
WARNING
POSITION. ALWAYS LOCATE HEATER ON A STABLE AND LEVEL SURFACE!
© 2021 Pinnacle Climate Technologies, Inc.
SAFETY INFORMATION
Top
Front
5 ft.
5 ft.
5 ft.
5 ft.
5 ft.
5 ft.
5 ft.
Sides: 3 ft. (5 ft*)
Floor:
Combustible
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING OR WHILE CONNECTED
TO A FUEL SOURCE
WARNING
material and contact with hot surfaces both
during use and while in storage.
– This heater is shipped from the factory
for use with propane (LP) gas only. Do not
convert to any other gas. Installation must
conform to local codes, or in their absence,
Rear
with the standard for the Storage and Handling
3 ft.
of Liquefied Petroleum Gases ANSI/NFPA 58
3 ft.
and the Natural Gas and Propane Installation
5 ft.
Code CSA B149.1.
– Gas supply connections should be checked by
using a 50/50 soap and water solution. Never
use a flame to check for gas leaks.
– Do not direct heater discharge towards the LP
cylinder unless it is at least 20 feet from the
heater.
– Use only the regulator and hose assembly
provided with this heater. Inspect the
regulator/hose assembly prior to each use
of the heater. If there is excessive abrasion
or wear, or if the hose is cut, replace it with
the proper assembly shown in the parts list
following manufacturer's specification, prior to
using the heater.
Minimum and Maximum Inlet Pressure
Min.
Max.
Propane Tank Top Heater User's Manual
5
The hose assembly shall be
pro tected from traffic, building
MH-16-TTC
MH-32-TTC
25 PSI
200 PSI
MH-360A-TTC

Publicité

loading

Ce manuel est également adapté pour:

Mh-32-ttcMh-16-ttc