Quick Installation Guide
Program schedule override (temporary)
1
Press + or - to adjust the temperature.
2
Once at the desired setpoint
temperature, no further action
is needed. The new setpoint
temperature will be held until the
next scheduled time period begins.
For more information on schedule
time periods, see "Program Schedule"
on page 11.
3
To cancel the Temporary Hold, Press
+ or - and then press Cancel.
Program schedule override (permanent)
1
Press + or - to adjust the temperature.
2
TEMPORARY HOLD is displayed
and the setpoint temperature flashes.
While it's flashing, press Hold (Mode)
button to change to Permanent Hold.
3
To cancel the Permanent Hold, press
+ or - and then press Cancel.
Wiring—conventional systems
Alternate wiring (conventional systems)
If labels do not match terminals, connect wires as shown below (see notes, below).
NOTES:
1. If you must connect
both R and Rc wires,
set the R Slider Tab
to the down position
(2 wires).
2. If your old
thermostat had both
R and RH wires, set
the R Slider Tab to
the down position (2
wires). Then connect
the R wire to the Rc terminal, and the RH wire to the R terminal.
3. If your old thermostat had only 1 C or C1 wire, connect it to the C terminal. If
your old thermostat had 2 C or C1 wires, wrap each separately with electrical
tape and do not connect them.
4. C does not power the thermostat display or operations; batteries are always
required.