4. Tighten the nut by hand. Use a small amount of
grease to make it easier to turn the nut.
5. Using a ring spanner, tighten the nut so that the
connection cover breaks out.
6. Once made a flue gas opening can be closed off
again with the supplied shut-off cover (A). Use the
mounting plate (C) and bolt M6x25 (D) to fit the
cover to the appliance (B); see the following figure.
7. Fit the connection collar (C) to the flue gas
opening (D) using the two brackets supplied (E)
and the fixing materials (A) and (B); see the
following figure.
Subject to change because of technical improvements
8. Use the supplied stove sealant for sealing the
connection collar and the cover with the appliance.
Connecting on the upper side
You need a special connection collar to connect on
the upper side. This is not supplied with the
appliance.
1. Remove one of the rectangular covers from the
upper side of the appliance.
2. Install the special connection collar on the opening
created.
3. Use the stove sealant supplied for sealing the
connection collar and the appliance.
Connecting via the attachment 5T
The attachment 5T increases the surface of the stove
that exchanges heat, thereby increasing efficiency.