Télécharger Imprimer la page

KitchenAid 740-0005 Instructions D'installation Et Guide D'utilisation Et D'entretien page 21

Publicité

Les langues disponibles

Les langues disponibles

Make Gas Connection
1.
Before making any connections, check to ensure the
natural gas inlet pressure falls between the allowable
range of 7" W.C. / 0.25 psi and 14" W.C. / 0.5 psi. If the
NG inlet pressure does not fall within this range, contact
your local gas supplier.
2.
A combination of pipe fittings must be used to connect the
grill to the existing gas line.
The 3.0 m (10 ft) PVC flexible gas supply hose design
certified by CSA must be used.
Pipe-joint compounds suitable for use with Natural
gas must be used. Do not use Teflon
There must be a certified manual shut-off valve in the
gas supply line near the grill for easy access.
3.
Connect the brass connector on one end of the 3.0 m (10
ft) PVC flexible gas supply hose to the Natural gas
pressure regulator.
4.
Connect the quick connector on the other end of the 3.0 m
(10 ft) PVC flexible gas supply hose to the rigid Natural
gas supply pipe.
† ®TEFLON is a registered trademark of Chemours.
Change Grill Main Burner Valve Orifices
1.
2.
®†
tape.
3.
4.
21
Remove the grates and flame tamers.
Remove the screw and clip that hold the burner in place.
Set the screw and clip aside.
Remove the burner from the grill by lifting the burner out.
Use a 6 mm socket and wrench or 6 mm nut driver to
remove the brass orifice from the end of gas valve. The
main NG burner orifice is located behind the LP orifice, so
no additional orifice needs to be installed.
A. Main burner orifice
IMPORTANT: Check that the orifice is properly installed
inside of the gas valve.
A

Publicité

loading

Ce manuel est également adapté pour:

750-0005