GH2 Activeline Beacon Technical Manual
When using several colours, the colour flashes 4 times, being lit for 55 ms and turned off for 440 ms.
Technical data
General
Operating modes
Remark:
Enclosure
Light element
Degree of protection
Operating temperature
Storage and transport temperature
Clamp capacity of terminals
Weight
Version with AC voltage
Operating voltage (Voltage between colour
terminals and terminal „N")
Current consumption
colour (white) on
Power consumption
Insulation class
Test signal:
Connection line or terminal not in order:
Connection fine or terminal in order:
Version with DC voltage
Operating voltage
(Voltage between colour terminal and
terminal „GND")
Tolerance of operating voltage
Current consumption
Power consumption at rated operating voltage
Insulation class
Test signal:
Connection line or terminal in order:
Connection line or terminal not in order:
6
GH2 ACTIIVELINE BEACON TECHNICAL MANUAL
2420 ms
Continuous light
one colour
The colour is conmuously on
more than one colour
990 ms turn-on time per colour
Blink light
one colour
220 ms tum-on time, 275 ms turn-off time
more than one colour
binks 2 times per colour
Flash light
one colour
55 ms turn-on time, 440 ms turn-off time
more than one colour
flashes 4 times per colour
The change of colour always takes place in the order green - yellow - red - blue - white
thermoplastic
polycarbonate
IP 54 according to EN60529
-25°C ... +60°C
-40°C ... +70°C
1,5 mm
0,3 kg
230 VAC , 50 ... 60 Hz
< 50 mA
< 12 W
II
A connection line and terminal test can be conducted with the signal at terminal
„LM"(Line Monitoring). The voltage between the terminals „LM" and „N" is measured.
Attention! Don't connect operating voltage to the „LM" terminal.
measured voltage
O V or operating AC voltage without DC component
measured voltage
1/2 operating AC voltage (± 20%) with DC component
24 VDC
±20%
colour (White) on
< 135 mA
< 4 W
III
A negative voltage (<24V) relative to terminal .GND" can be connected to terminal „LM".
The measured current correlates to a load of 10 kΩ.
disconnection
No current
short circuit
The measured current correlates to a load of less than 2 kΩ.
TMF0074.A