The specified vibration value was measured with a
standardised test procedure. It can be used to
compare products or to make an initial assess-
ment of the exposure. The vibration emissions may differ
from the specified value, depending on how the power
tool is used. Operating personnel must be protected with
defined safety measures based on the estimated expo-
sure under the actual conditions of use (these must take
into account all phases of the operating cycle, e.g. the
times when the power tool is switched OFF and the times
it is switched ON, but is not under load).
2.4 o
perAting conditions
Temperature range during operation: 0 to +50°C
Relative air humidity: 95 % at +10°C not condensed
3.
haNDLINg
3.1 p
rotectiVe deVises
The hand protection is preinstalled at the works.
If necessary you can detach the hand protection by loos-
ening two crews.
3.1.1 p
rotection of the mAchine
s
tArting current limitAtion
The electronically controlled soft starting provides for
smooth starting of the machine. Due to the low machine
starting current a 16 A fuse is adequate.
t
-
emperAture
dependent overloAd protection
For protection against overheating, when a critical tem-
perature is reached the electronic safety feature switches
into the cool-down mode.
Then the machine continues to run at approx. 1,300 rpm
and the electronic constant speed control is deactivated.
After a cool-down time of approx. 10 - 20 sec. the ma-
chine is again ready for operation.
Turn the machine off and back on again to activate the
electronic constant speed control.
When the machine is at operating temperature the tem-
perature-dependent overload protection reacts at a cor-
respondingly earlier time.
o
vervoltAge
On short-time outage of the power voltage (pulled power
connector, unstable power voltage etc.) the machine will
stop. On recovery of the power voltage the machine has
to be turned off and back on again. The machine is then
ready for operation.
3.2 r
accessible position for special work operations.
/ o
PERaTIoN
Remove the four screws and carefully rotate the gearbox
head into the desired position. Screw in the screws and
tighten down.
3.3 g
3.3.1 f
Clean backing flange, clamping nut and backing flange
surface of the grinding tool.
Place backing flange on the spindle.
/
restArting protection
otAtion of geArBox heAd
The gearbox head can be rotated relative to the
stator housing in steps of 90° which enables the
ON/OFF switch to be brought into a more easily
rinding tools
Use only grinding tools whose admissible maxi-
mum speed is equal to or higher than the no-load
speed of the machine.
Use only clean tools!