  • FRANÇAIS, page 69
Trouble or fault
The battery runs down more
quickly than usual.
The battery doesn't engage
with an audible click.
The angle grinder or battery
gets very hot.
The motor has no braking
effect.
11
Disposal
WARNING
Risk of injury due to incorrect disposal! Health hazards due to escaping gases or liquids.
▶ DO NOT send batteries through the mail!
▶ Cover the terminals with a non-conductive material (such as electrical tape) to prevent short circuiting.
▶ Dispose of your battery out of the reach of children.
▶ Dispose of the battery at your Hilti Store, or consult your local governmental garbage disposal or public
health and safety resources for disposal instructions.
Most of the materials from which Hilti products are manufactured can be recycled. The materials must be
correctly separated before they can be recycled. In many countries, your old tools, machines or appliances
can be returned to Hilti for recycling. Ask Hilti Service or your Hilti sales representative for further information.
▶ Do not dispose of power tools, electronic equipment or batteries as household waste!
12
Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
13
Further information
For more information on operation,
qr.hilti.com/manual?id=2233920&id=2233921
This link is also to be found at the end of the documentation, in the form of a QR code.
Originele handleiding
1
Informatie over de handleiding
1.1
Bij deze handleiding
Lees voor ingebruikname deze handleiding door. Dit is vereist voor veilig werken en storingsvrij gebruik.
De veiligheidsinstructies en waarschuwingsaanwijzingen in deze handleiding en op het product in acht
nemen.
De handleiding altijd bij het product bewaren en het product alleen met deze handleiding aan andere
personen doorgeven.
40
Nederlands
Possible cause
Very low ambient temperature.
The retaining lug on the battery is
dirty.
Electrical fault
Clogged air vents
Battery is discharged.
Product is momentarily
overloaded.
technology,
environment and recycling,
Action to be taken
▶ Allow the battery to warm up
slowly to room temperature.
▶ Clean the retaining lug and
re-insert the battery.
▶ Switch the product off immedi-
ately, remove the battery, keep
it under observation, allow it
to cool down and contact Hilti
Service.
▶ Regularly clean the air vents.
▶ Change the battery and charge
the empty battery.
▶ Switch the product off and then
on again.
follow this link: