LONG TIME SHUT DOWN
1. Check the fuel tank for leaks.
2. Drain the accumulated water in the pump completely.
3. Remove the spark plug and clean it (see chapter 7. Maintenance).
4. Clean the fuel filter in the fuel cock and the fuel tank (see chapter 7.
Maintenance).
5. Clean the air filter (see chapter 7. Maintenance).
During the cold winter seasons, be sure that the accumulated water in the
pump is completely drained!
All manuals and user guides at all-guides.com
1. Clean in solvent
2. Wipe off
3. Insert
30