Condensing unit runs for long
periods of time.
Cabinet Temperature Is too warm.
Cabinet is noisy.
All manuals and user guides at all-guides.com
Excessive amount of warm product
Placed in cabinet.
Prolonged door opening or door
ajar.
Door gasket(s) not sealing
properly.
Dirty condenser coil.
Evaporator coil iced over.
Thermostat set too warm.
Blocking air flow.
Excessive amount of warm product
Placed in cabinet.
Fuse blown or circuit breaker
tripped.
Dirty condenser coil.
Prolonged door opening or door
ajar.
Evaporator coil iced over.
Loose part(s).
Tubing vibration.
For service call 1-800-465-0234.
7
Troubleshooting
Allow adequate time for Product to
cool down.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
Ensure gaskets are snapped in
Completely. Remove gasket and
Wash with soap and water. Check
condition of gasket and Replace if
necessary.
Clean the condenser coil.
Unplug unit and allow coil to
defrost. Make sure thermostat is
not set too cold. Ensure that door
gasket(s) are sealing properly.
Set thermostat to lower
Temperature.
Re-arrange product to allow for
Proper air flow. Make sure there
Is at least four inches of clearance
from evaporator.
Allow adequate time for product to
cool down.
Replace fuse or reset circuit
breaker.
Clean the condenser coil.
Ensure doors are closed when not
in use. Avoid opening doors for
long periods of time.
(See above)
Locate and tighten loose part(s).
Ensure tubing is free from contact
with other tubing or components.