5,
6,
Using UL-listed/CSA
approved twist-on connectors sized to
connect power supply cord to 16-gauge dishwasher wire,
connect the black wire from the power supply cord to the
black wire on the terminal box.
Tighten the conduit connector screws to secure the power
supply cord.
1,
Measure the cabinet opening height.
7. Insert tabs on the left-hand side of the terminal box cover.
8. Using a V4"nut driver and previously removed screw, reinstall
the terminal box cover with the wires inside terminal box.
2,
Adjust the dishwasher leg height according to the following
chart. Turn both of the leveler legs to the same height.
Height
Adjusted
Leg Height
Adjusted
Leg
(H)
Height (X)
(H)
Height (X)
33W' (85.1 cm) 0"
34%" (87.4 cm)
%" (2.2 cm)
338/8 '' (85.4 cm) V8" (0.3 cm)
34W' (87.7 cm)
1" (2.5 cm)
333/4 '' (85.7 cm) V4" (0.6 cm)
348/8 '' (88 cm)
1V8" (2.8 cm)
337/8 '' (86 cm)
3/8"(1 cm)
343/4 '' (88.3 cm)
1V4" (3.1 cm)
34" (86.4 cm)
V2" (1.3 cm)
347/8 '' (88.6 cm)
13/8"(3.5 cm)
34V8" (86.7 cm) 8/8"(1.6 cm)
35" (88.9 cm)
1V2" (3.8 cm)
34V4" (87 cm)
3/4"(1.9 cm)
\\
\
\
9. Check that no wires are pinched by the cover.
NOTE: Do not plug power supply cord into outlet until instructed.
11