3.4
Technical data for Europe
Dimensions (LxWxH)
72.5 x 50 x 12 mm (without plug connector)
Operation
-37 °C to +75 °C
Temperature
Storage
-40 °C to +85 °C
Weight
30 g
Plug-in module, Induction loop detector
Equipment type
1/2-channel
Protection type
IP 00
Protection class
--
Supply voltage
24 VDC
Power consumption
max. 2 W
Current carrying capacity
--
Connection/interface
X1/X2: Power supply, outputs, 2x MOLEX
socket, 5-pole
X3: Loops 1/2, 4-pole terminal blocks,
5.0 mm pitch
Diagnostics: USB AB mini socket, 5-pole
Battery
--
Other
3 LEDs to indicate the operating status
Humidity
<95 % not dewing
Inductance
20-700 µH, recommended 100-300 µH *
Frequency
25-130 kHz, 2 stages
Sensitivity
0,01 % - 2,55 % (f/f) in 255 steps
Loop
Holding time
1 - 255 minutes or infinitely
Feed
max. 200 m
Resistance
max. 20 Ohm, inc. loop feed
NOTE
* It is possible that given loop inductances outside the recommended range,
only one frequency stage is available. The maximum possible loop
resistances have been reduced for small loop inductances outside the
recommended range.
Cable size
Connection
flexible with wire
rigid
end ferrule
2
X3 (1.1 - 2.2)
0.2 - 2.5 mm
0.25 - 1.5 mm
Sensors
VEK_MNST12_Install_rev4_mul
3.5
UL-Ratings
Supply
Class 2 output
Maximum surrounding air
temperature
Degree of pollution
Battery
Connection description
NOTE
The induction loop detector VEK MNST1/VEK MNST2 is only intended to be
located in Class 2 circuits and is only intended for installation inside the
FEIG ELECTRONIC Power Conversion Equipment, series TST.
Connection
X3 (1.1 - 2.2)
In the field-wiring area, provisions for wiring for Class 2 and Class 3 circuits
must meet the requirements for separation from Class 1 circuits in accordance
with Section 725 of the National Electrical Code, ANSI/NFPA 70 and Section 16
of the Canadian Electrical Code. Separation from power and lighting circuits is
required for Class 2 by one of the following means:
a)
a permanent barrier shall be provided to separate the field installed Class
2 conductors of secondary circuits from all other circuits or;
b)
provisions need to be made to route the Class 1 or power circuit
conductors in order to maintain a minimum 1/4-in (6.35 mm) separation
from the conductors of the Class 2 circuits.
E-File No. E218753
3.6
Assembly and connection
DANGER
Risk of electric shock!
Before connecting the accessories, switch off the supply voltage of the
controller!
Tightening
Do not switch on the supply voltage of the controller again until the
torque
installation of the accessories has been completed, the controller is
covered and no live parts can be touched.
2
0.35 – 0.4 Nm
VEK MNST1/2
24 VDC / max. 2 W, Class 2
--
85 °C
For use in an environment with pollution
degree 2.
--
X1: 2 switching signal outputs
X2: 1 switching signal output, RS-485
interface, 5 V / max. 50 mA
X3: loop channels 1/2
Cable size
Tightening torque
NEC wiring
24 – 14 AWG
4 Lb-in
Class 2
(0.2 – 2.1 mm²)
(0.4 Nm)
4 | 7
Lange Straße 4 | D-35781 Weilburg
Tel. +49 6471 3109-0 | Mail:
ATTENTION
Connect connection terminals before connecting to the plug connectors! Only
thus is it possible to ensure a safe contact of the connection terminals to the
plug connectors.
The description of the connection to the controller can be found in the
assembly instructions of the respective controller.
3.6.1 Pin assignment
Connection
Pin
Designation
X1
1
Supply
2
Supply
3
Supply
4
Trigger OUT2
5
Trigger OUT1
X2
1
Trigger OUT3
2
RS 485 B-Channel
3
RS 485 A-Channel
4
unallocated
5
unallocated
X3
1.1, 1.2
Loop channel 1
2.1, 2.2
Loop channel 2
3.7
Adjustment and diagnosis
The inductive loop detector can only be set via parametrization of the door
controller.
The current loop frequency and the detuning can be displayed via the
diagnostic parameters in the door controller. Further details regarding the
inductive loop detector e.g. the current frequency of the current detuning, the
occupation duration etc. can be displayed via the service programme (detector
tool) via the USB interface on the computer.