TD-C100.qxd 14.6.2 16:26 ページ 3
9. TROUBLESHOOTING
SYMPTOM
CAUSE
Unit does
- Power cut.
not work.
- The plug has been
plugged improperly.
- The FULL LAMP is
ON. Tank is full.
- The DEFROST LAMP
is ON.
FULL lamp is
- The tank is not insert-
ON even the
ed properly.
water tank is
empty.
- The float of tank is not
placed properly.
The product
- The filter is dusty or air
does not de-
outlet is clogged.
humidify.
- Surrounding tempera-
ture and humidity are
low.
Operation
- The filter is dusty
sound is
- The unit operates on
loud.
the rough place.
The drain
- The unit leans.
water is
leaked.
- Move the unit with wa-
ter in the tank.
- The float is not in the
proper position.
- Take the water tank
out soon after stop-
ping the operation.
BEFORE CALLING FOR SERVICE
The following are not defects.
A hissing noise or hollow
sound:
A squeaking noise:
Odor:
The unit does not start nor
change operation mode
immediately:
All manuals and user guides at all-guides.com
SOLUTION
- Wait for power to be
supplied again.
- Plug in again.
- Remove the drain wa-
ter from the drain
tank.
- When the room tem-
perature is under
12˚C, the heat ex-
changer is sometimes
frosted. And the unit
starts defrosting mode
automatically. During
this mode, DEFROST
LAMP is ON, and wait
for a while.
- Take the water tank
out once, and push it
back to the proper po-
sition.
- Place the float in the
proper position.
- Clean the filter and air
outlet.
- As the temperature
and humidity are low-
er, the amount of de-
humidification is also
lower.
- Clean the filter.
- Operate at the flat
place.
- Operate at the flat
place.
- Remove the water at
first, and then you can
move the product.
- Place the float proper-
ly.
- The product keeps
draining even the unit
stops operating. Wait
for approx. 5mins.
This sound is generated from the
e
refrigerant flowing within pipes.
This noise is generated from the
e
unit when it is expands or con-
tracts with temperature changes.
Such odor as tobacco, cosmet-
e
ics, or foods may accumulate in
the unit.
To prevent overloading the com-
e
pressor motor, the unit will be
stopped for more than 3 minutes.
10. SPECIFICATIONS
MODEL
DEHUMIDIFYING CAPACITY
POWER SOURCE
POWER CONSUMPTION
OPERATING CURRENT
AIR FLOW (MAX.)
OPERATING TEMP. RANGE
DIMENSIONS (WxHxD)
WEIGHT
COMPRESSOR
REFRIGERANT
NOTE: Dehumidifying capacity will vary according to temperature
and humidity of the room.
CONTAINS FLUORINATED GREENHOUSE GASES COVERED BY
THE KYOTO PROTOCOL.
HERMETICALLY SEALED SYSTEM
3
ENGLISH
TD-C100
10 L/D (30˚C, 80%RH)
Single Phase 220-240V, 50Hz
205 W
0.8A
45 m
3
/h
5˚C ~ 32˚C
230 x 386 x 230 mm
8.5kg
ROTARY
R-134A / 110g

Publicité