The DIP SWITCH of the SW 1 strip
change usage function based on
operational mode se in the sensor (DIP
1 of the SW 2 strip):
DIP/RELAY mode: in this mode the DIP
SWITCHES are used to configure
operation of the two section (infrared
and microwave) as shown on the table
at the side.
PC/BUS mode: in this mode the DIP
SWITCHES are used to assign an
E
address to the sensor (see table on the
next page).
N
However, even in PC/BUS Mode is is
G
possi ble
temporarily
SWITCHES from SW 1 to configure the
two sections as if the DIP/RELAY Mode
was selected.
In order to do this, it is sufficient to:
1. Set the DIP SWITCH according to
the desired configuration.
2. Position DIP SWITCH 1 of SW 2
in the ON position.
3. Bring DIP SWITCH 1 of SW 2 to
the OFF position.
4. Position the DIP SWITCH of the
SW 1 based on the address to be
assigned to the sensor.
All manuals and user guides at all-guides.com
In operation with relays, the configurations that can be programmed with the Dip Switch SW1 strip are:
DIP 1 OFF DEFAULT
DIP 2 OFF
DIP 1 ON LOW
DIP 2 OFF
DIP 1 OFF MEDIUM
DIP 2
ON
DIP 1 ON HIGH
DIP 2
ON
DIP 3 OFF DEFAULT
us e
DIP
DIP 4 OFF
DIP 3
ON APPROACHING
DIP 4 OFF
DIP 3 OFF MOVING AWAY
DIP 4
ON
DIP 3
ON NO CONTROL
DIP 4
ON
AND
OFF
DIP 5
SECURITY
ON
(not recommended for
external use)
DIP 6
NOT USED
DIP 7
NOT USED
DIP 8
NOT USED
SW1 - FUNCTIONS
INFRARED SECTION CONFIGURATION
In this configuration, the infrared section has a default sensitivity (studied
for standard use) and executes a digital analysis of the signals.
in this configuration, the infrared section has a low sensitivity compared
to the default and executes a digital analysis of the signals which is
more severe than the default one and considers a dual impulse.
in this configuration, the infrared section has a medium sensitivity
compared to the default and executes a digital analysis of the signals
which is more severe than the default one.
in this configurations, the sensor has a high sensitivity and detects any
signal analysing amplitude and frequency.
MICROWAVE SECTION CONFIGURATION (only OUTSPIDER DT)
in this configuration, the microwave section executes a digital analysis
of the signal.
in this configuration, the microwave section analyses the signal while
considering only the movements approaching the sensor
in this configuration, the microwave section analyses the signal while
considering only the movements moving away from the sensor
in this configuration, the microwave section detects any movement while
analysing the intensity and frequency of the signal.
SENSOR OPERATION (only OUTSPIDER DT)
the alarm is generated only when both sections (infrared and microwave)
detect the adequate signal
the sensor works in OR integrated; it therefore generates an alarm signal
even when the individual section detects a series of valid signals
NOTE: by default, the DIP SWITCHES are all positioned at OFF