Trimmer for
adjusting
microwave capacity,
increases
when turned
clockwise
MW
Buzzer for
GIALLO
alarm signalling
LED
Yellow Steady:
P a ss i ve i nfra re d a la rm
signal
Fast flashing:
Antimask alarm signal
Slow flashing:
Dirty lenses fault signal
Flashing:
Alternately with red LED for
about 60 seconds at first
feeding
Red
Steady:
General alarm signal
Flashing:
Alternately with yellow LED
for about 60 seconds at
first feeding
Green Steady:
Microwave section alarm
signal
All manuals and user guides at all-guides.com
ON
SW1
1 2 3 4
5 6 7 8
ON
1 2 3 4
5 6 7 8
SW2
Connector for connecting the module mod.
USB-OUT (item 1135105) for direct handling of
1.0
1.5
2.2
the sensor by way of the PC.
2.7
ROSSO
VERDE
USB
With the USB-OUT adapter it is possible to
connect the sensor directly to the PC for managing
through the HPWIN software.
In the DIP/RELAY mode: through this connection
it is possible to display the configuration made
by way of the DIP SWITCH, display actual sensor
operation and acquire the download of the last
1920 events to the pc.
In PC/BUS mode: through this connection it is
possible to display and modify the configuration,
even is previously completed by way of DIP
SWITCH, adjust microwave sensitivity, display
actual sensor operation and acquire the download
of the last 1920 events to the pc.
SW 1: See next page
- 35 -
SW2 - FUNCTIONS
ON Connection by DIP/RELAY
1
OFF Connection by PC/BUS
ON Buzzer enabled
2
OFF Buzzer excluded
ON Red LED enabled Alarm
3
OFF Red LED excluded Alarm
ON Green LED enabled Microwave
4
OFF Green LED excluded Microwave
ON Yellow LED enabled Antimask
5
Yellow LED excluded Antimask
OFF
and Dirty lenses
ON AUX input activates Alarm relay
6
OFF AUX input activates Tamper relay
ON Antimask function enabled
7
OFF Antimask function excluded
ON AUX input management enabled
8
OFF AUX input management disabled
IMPORTANT: In the mode withPC/BUS,
the functions configurable through DIP
SWITCH SW2 cannot be modified through
the PC except for the ANTIMASK function
(DIP 7)
DEFAULT
DIP SWITCH
1
2
3
4
5
6
ON
ON
ON
ON
ON OFF ON
E
N
G
7
8
ON