Oscilloscope function
This application makes it possible to verify sensor signals in real time:
W Y
E
N
NOTE: OutSpider PA, to hide the signal from the lower infrared it is necessary to remove the check mark from both the red and the yellow box, to
G
hide the upper infrared signal instead it is sufficient to remove the check mark from the white box. OutSpider DT, each reference corresponds
to the value indicated.
Signal from the infrared section (red and white line):
Œ
All manuals and user guides at all-guides.com
R G
White Line
Red Line
•
Timing scale: selects the timing scale on the y-axis.
Traces to be displayed: enables/disables trace display.
Signals:
Red line (R): indicates the infrared signal that reads the lower part of
the target
White line (W): indicates the infrared signal that reads the upper part
of the target
Yellow line (Y): indicates the microwave signal (OutSpider DT)
Green line (G): indicates the signal from the anti-masking circuit
Both infrared sections do not detect signals.
Œ
In the first part of the diagram it is the only infrared that reads the upper
part of the target (white line) that detects a signal. The infrared section does not
generate an alarm.
•
In the second part of the diagram it is the only infrared that reads the lower
part of the target (red line) that detects a signal. The infrared section does not
generate an alarm.
For an adequate operation of the two infrared sections, find the correct
inclination for the sensors so that the two signals, crossing the area to be
protected, are nearly the identical.