Télécharger Imprimer la page

AVS Electronics OUTSPIDER PA Manuel D'installation

Masquer les pouces Voir aussi pour OUTSPIDER PA:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

All manuals and user guides at all-guides.com
Curtarolo (Padova) Italy
www.avselectronics.com
OUTSPIDER PA
Sensore a doppio infrarosso passivo
OUTSPIDER DT
Sensore a microonda e
doppio infrarosso passivo
da esterno e interno
IST0777V2.0
- 1 -
da esterno e interno
Sistema di qualità
certificato
ISO 9001:2008
I
T
A
E
N
G
F
R
A

Publicité

loading

Sommaire des Matières pour AVS Electronics OUTSPIDER PA

  • Page 1 All manuals and user guides at all-guides.com Sistema di qualità certificato ISO 9001:2008 Curtarolo (Padova) Italy www.avselectronics.com OUTSPIDER PA Sensore a doppio infrarosso passivo da esterno e interno OUTSPIDER DT Sensore a microonda e doppio infrarosso passivo da esterno e interno IST0777V2.0...
  • Page 2 Linea telefonica (modem) ............15 Gestione sensori ................... 16 Regolare data ed ora ................. 16 Visualizzazione parametri ..............16 Stato Uscite ..................16 Gestione parametri ................17 Schermata OutSpider DT ............17 Schermata OutSpider PA ............17 - 2 -...
  • Page 3 All manuals and user guides at all-guides.com Accessori ACCESSORI A CORREDO SNODO composto da: A. Staffa lato muro B. Snodo intermedio C. Snodo lato sensore D. Vite TC-C M6 INOX E. Dado M6 INOX F. Rondella dentata TAMPER composto da: A.
  • Page 4 OUTSPIDER è dotato di un circuito che evita il blocco del microprocessore. w OUTSPIDER PA è dotato di un buzzer e di una serie di led per dare una segnalazione ottico-acustica (Walk Test) anche se al sensore è applicato il blocco.
  • Page 5 All manuals and user guides at all-guides.com Descrizione del funzionamento del sensore in modalità “Default” In questa modalità la sezione infrarossa discrimina gli allarmi operando i seguenti controlli: w ampiezza e simmetria del segnale: la forma d’onda deve superare delle soglie minime sia nel verso positivo che in quello negativo; inoltre le larghezze delle semionde devono essere proporzionate w il livello di energia del segnale deve essere superiore ad un valore minimo I precedenti controlli vengono svolti sui due infrarossi in maniera indipendente l’uno dall’altro.
  • Page 6 All manuals and user guides at all-guides.com Copertura Evitare che nella zona di rilevazione del sensore vi siano oggetti che coprano il campo di lettura o che vi siamo piante che con il tempo po- trebbero modif icare l’ambiente circo- 2,7 metri stante.
  • Page 7 All manuals and user guides at all-guides.com Apertura sensore e rimozione scheda Installazione della piastra a muro e a palo Per togliere il coper- chio, alzare prima la par- Fori per il fissaggio te inferiore (1) e poi della piastra a parete sganciarlo dalla guida sulla parte superiore (2) Fori per il fissaggio della...
  • Page 8 All manuals and user guides at all-guides.com Installazione Antistrappo Fissaggio della base alla piastra Predisposizioni per l’accesso dei Con snodo fili per i collegamenti Agganciare la base del sonsore ai due fermi sulla parte inferiore della piastra metallica Punto di fissaggio modulo tamper Fissare la base del sensore alla piastra metallica con le due viti in...
  • Page 9 All manuals and user guides at all-guides.com Fissaggio scheda Cambio lenti Rimuovere le 6 viti di fermo Estrarre il supporto della lente Inserire la scheda facendo combaciare gli scansi con i fermi Sganciare la lente dal supporto facendo una leggera pressione sui quattro fermi laterali Inserire la lente seleziona- Far scorrere...
  • Page 10 La programmazione può avvenire da PC tramite il In questa condizione si comporta come segue: software HPWIN o, eseguendo una particolare proce- OUTSPIDER PA: dura, si può utilizzare lo stesso metodo della modalità a • il relè di allarme rimane chiuso •...
  • Page 11 All manuals and user guides at all-guides.com SW 1: Vedi pagina successiva SW2 - FUNZIONI Trimmer per la 1 2 3 4 5 6 7 8 regolazione della ON Modalità DIP portata della OFF Modalità PC 1 2 3 4 5 6 7 8 microonda, aumen- ON Buzzer abilitato...
  • Page 12 All manuals and user guides at all-guides.com SW1 - FUNZIONI I DIP SWITCH del banco SW 1 cam- Nel funzionamento a relè, le configurazioni programmabili con il banco di Dip Switch SW1 sono: biano la funzione d’uso in base alla modalità...
  • Page 13 Sensore DIP1 DIP2 DIP3 DIP4 DIP5 OutSpider PA e OutSpider DT sono provvisti di un circuito antimascheramento, formato da un ricevi- tore RX centrale e quattro trasmettitori TX ad infrarossi attivi posizionati ai lati dei sensori PIR, che rileva gli ostacoli posti di fronte al sensore fino ad una distanza di circa 5 cm.
  • Page 14 All manuals and user guides at all-guides.com Funzioni speciali Grazie al software da PC HPWIN, è possibile sfruttare al meglio le potenzialità della tecnologia digitale. HPWIN permette per ogni sensore: Verifica: Ritorno alla schermata iniziale grafico segnali dei due infrarossi (selezionabile) Attivazione della connessione USB /Telefonica, per la vi- grafico segnale microonda solo Mod.
  • Page 15 All manuals and user guides at all-guides.com Tipologia connessione per gestione con software HPWIN Il sensore può essere collegato al PC tramite: Connessione Seriale RS232 (non utilizzata) Connessione USB Linea telefonica (modem) Connessione USB Questo tipo di connessione permette il collegamento del sensore al PC tramite: l’adattatore mod.
  • Page 16 All manuals and user guides at all-guides.com Gestione sensori L’accesso a questo menù impone la scelta del tipo di connessione: 1- Seguire la procedura in base al tipo di connessione da eseguire NOTA: se fosse una connessione in USB, potrebbe richiedere l’installazione dei driver per il riconoscimento della periferica. Se i driver non vengono riconosciuti automaticamente, è...
  • Page 17 % Sensibilità microonda: regolazione della sensibilità della microonda (tramite il software, si può solo diminuire rispetto al valore impostato con il trimmer RV1 nel sensore) Schermata OutSpider PA Sensibilità OutSpider: selezione della sensibilità della sezione infrarossi On/Off Antimask: gestione della funzione antimascheramento Memorizza allarmi sempre: memorizza tutti gli allarmi o solo quelli ad impianto inserito NOTA: tramite il software non è...
  • Page 18 Linea verde (V): indica il segnale del circuito antimascheramento NOTA: OutSpider PA, per nascondere il segnale dell’infrarosso inferiore è necessario togliere il segno di spunta sia dal bollino rosso che dal bollino giallo, mentre per nascondere il segnale dell’infrarosso superiore è sufficiente togliere il segno di spunta dal bollino bianco.
  • Page 19 All manuals and user guides at all-guides.com Œ I segnali rilevati dai due infrarossi non corrispondono. La sezione infraros- Œ • Ž si segnala l’allarme solo se il segnale supera una certa soglia e se il sensore è settato nella configurazione ALTA. •...
  • Page 20 Indirizzo del sensore (non gestito in connessione USB) Impostazioni data ed ora del sensore Tensione di alimentazione Temperatura nel sensore Stato del sensore: OutSpider PA: Tamper - Allarme - Antimask OutSpider DT: Tamper - Allarme generale - Antimask - Allarme sezione microonda...
  • Page 21 All manuals and user guides at all-guides.com Storico Eventi L’accesso a questo menù impone la scelta del tipo di connessione: 1- Seguire la procedura in base al tipo di connessione da eseguire NOTA: se fosse una connessione in USB, potrebbe richiedere l’installazione dei driver per il riconoscimento della periferica. Se i driver non vengono riconosciuti automaticamente, è...
  • Page 22 All manuals and user guides at all-guides.com Archivio Registrazioni • L’archivio delle registrazioni permette di visualizzare i segnali memorizzati dall’installatore sul PC con la procedura di “Registrazione “ descritta sul capitolo “Gestione Sensori”. Œ Entrando in questo archivio si accederà ad un database dove i vari file saranno salvati con data/ora, descrizione e durata della registrazione.
  • Page 23 Il prodotto oggetto della presente dichiarazione è conforme alle prescrizioni fondamentali della Diret- tiva 1999/5/CEE (R&TTE) sugli apparati radiotrasmittenti di debole potenza e sull’uso delle frequenze dello spettro radioelettrico, in accordo anche con la raccomandazione CEPT 70-03. AVS ELECTRONICS Marca Modello...
  • Page 24 Lenti copertura infrarosso protetta da fusibile. Grado di protezione IP 65 IP 65 AVS ELECTRONICS S.p.a. si riserva il diritto di apportare modifiche in qualsiasi momento e senza preavviso. - 24 -...
  • Page 25 All manuals and user guides at all-guides.com Quality system certified ISO 9001:2008 Curtarolo (Padova) Italy www.avselectronics.com OUTSPIDER PA Double passive infrared detector for outdoors and indoors OUTSPIDER DT Microwave and double passive infrared sensor for outdoors and indoors IST0777V2.0 - 25 -...
  • Page 26 Phone line (modem) ..............39 Sensors management ................40 Adjust date and time ................. 40 Display parameters ................40 Status of Outputs ................40 Parameters management ..............41 OutSpider DT Screen ............... 41 OutSpider PA Screen ............... 41 - 26 -...
  • Page 27 All manuals and user guides at all-guides.com Accessories SUPPLIED ACCESSORIES JOINT made up of: A. Wall bracket B. Intermediate joint C. Sensor-side joint D. Stainless steel TC-C M6 screw E. Stainless steel M6 nut F. Toothed washer TAMPER made up of: A.
  • Page 28 OUTSPIDER is equipped with a circuit that avoids that the microprocessor goes in block. w OUTSPIDER PA is equipped with a buzzer and a series of LED in order to give an optical-acoustic signal (Walk Test) even if a block is applied to the sensor.
  • Page 29 All manuals and user guides at all-guides.com Description of sensor operation in “Default” mode In this mode the infrared section discriminates the alarms by operating the following controls: w signal width and symmetry: the wave shape must exceed minimum thresholds, both in the positive and in the negative direction; besides, the width of the half-waves must be proportionate.
  • Page 30 All manuals and user guides at all-guides.com Coverage Avoid the presence of objects in the sensor detection area that cover the read range or that there are plants that over time modify the surrounding environment. 2.7 metres (max.) 2,2 metres (max.
  • Page 31 All manuals and user guides at all-guides.com Sensor opening and board removal Wall and pole plate installation To remove the cover, first lift the bottom part Holes for fixing the (1) and then unhook it plate to the wall from the upper part of the guide (2).
  • Page 32 All manuals and user guides at all-guides.com Anti-tamper Installation Fixing the base to the plate Presettings for access of With joint connection wires Hook the base of the sensor to the two stops on the lower portion of the metal plate Fixing point for tamper module Fix the base of the sensor to...
  • Page 33 All manuals and user guides at all-guides.com Fixing the board Lens change Remove the 6 set screws. Remove the lens support. Insert the board until the notches coincide with the stops Unhook the lens from the support by slightly pressing on the four side stops.
  • Page 34 The programming can occur by PC via the HPWIN In this condition, act as follows: software or via the Dip mode following a special procedu- OUTSPIDER PA: In the PC mode, although previously set in the detector • the alarm relay remains closed by the DIP-SWITCH, the configuration can be modified •...
  • Page 35 All manuals and user guides at all-guides.com SW 1: See next page SW2 - FUNCTIONS Trimmer for adjusting 1 2 3 4 5 6 7 8 ON Connection by DIP/RELAY microwave capacity, OFF Connection by PC/BUS 1 2 3 4 5 6 7 8 increases ON Buzzer enabled...
  • Page 36 All manuals and user guides at all-guides.com SW1 - FUNCTIONS The DIP SWITCH of the SW 1 strip In operation with relays, the configurations that can be programmed with the Dip Switch SW1 strip are: change usage function based on operational mode se in the sensor (DIP INFRARED SECTION CONFIGURATION 1 of the SW 2 strip):...
  • Page 37 Sensor DIP1 DIP2 DIP3 DIP4 DIP5 OutSpider PA and OutSpider DT are equipped with an anti-masking circuit, made of a central RX receives and four active infrared TX transmitters positioned on the sides of the PIR sensors, that detects obstacles placed in front of the sensor up to a distance of about 5 cm.
  • Page 38 All manuals and user guides at all-guides.com Special functions Thanks to the software from HPWIN PC, it is possible to make the best use of digital technology potential. HPWIN allows each sensor: Check: Return to the initial screen chart of signals from the two infrared (selectable) Activation of the USB / Phone connection, for displaying chart of microwave signal only OUTSPIDER DT Mod.
  • Page 39 All manuals and user guides at all-guides.com Type of connection for managing with HPWIN software The sensor can be connect to the PC by way of: RS232 Serial Connection (not used) USB Connection Phone line (modem) USB connection This type of connection makes it possible to connect the sensor to the PC by way of: the OUTUSB mod.
  • Page 40 All manuals and user guides at all-guides.com Sensors management Access to this menu require a choice in type of connection: 1- Follow the procedure based on the the type of connection to be carried out NOTE: if it is a USB connection, it may require installation of drivers for recognising the peripheral device. If the drivers are not recognised automatically, it is necessary to specify the following file path to the operating system C:\Programmi\Xwin\Driver\ and select the stmcdcAVS.inf file 2- Select the address of the sensor and/or the satellite on HPWIN and then chose “Connetti (Connect)”...
  • Page 41 % Microwave sensitivity: adjustment of microwave sensitivity (by way of software, it is only possible to decrease it compared to the value set for the sensor with the RV1 trimmer) OutSpider PA Screen OutSpider Sensitivity: selecting sensitivity of the infrared section Antimask On/Off: handles the Antimask function...
  • Page 42 Green line (G): indicates the signal from the anti-masking circuit NOTE: OutSpider PA, to hide the signal from the lower infrared it is necessary to remove the check mark from both the red and the yellow box, to hide the upper infrared signal instead it is sufficient to remove the check mark from the white box. OutSpider DT, each reference corresponds to the value indicated.
  • Page 43 All manuals and user guides at all-guides.com Œ The signals detected by the two infrared do not correspond. The infrared Œ • Ž section signals an alarm only if the signal exceed a certain threshold and if the sensor is set with the HIGH configuration. •...
  • Page 44 NOTE: If connected to a sensor by way of USB, it displays the status in real time, if connected by way of XSATHP satellite, it displays the status of all active sensors connected to the actual satellite. OutSpider DT OutSpider PA Elements displayed: Sensor address (not managed with a USB connection)
  • Page 45 All manuals and user guides at all-guides.com Events Historical file Access to this menu require a choice in type of connection: 1- Follow the procedure based on the the type of connection to be carried out. NOTE: if it is a USB connection, it may require installation of drivers for recognising the peripheral device. If the drivers are not recognised automatically, it is necessary to specify the following file path to the operating system C:\Programmi\Xwin\Driver\ and select the stmcdcAVS.inf file.
  • Page 46 All manuals and user guides at all-guides.com Recordings Archive • The recordings archive makes it possible to display signals saved on the PC by the installer with the “Registrazione (Recording) “ procedure described in the “Gestione Sensori (Sensors Management)”. Œ By entering this archive one accesses a database where the various files are saved with date/time, description and recording duration.
  • Page 47 This product subject of this declaration conforms to the fundamental requirements of Directive 1999/ 5/CEE (R&TTE) on weak power radio transmitting equipment and the use of the radio electric spectrum, also in agreement with recommendation CEPT 70-03. AVS ELECTRONICS Brand Model...
  • Page 48 Infrared cover lenses Protection rating IP 65 IP 65 AVS ELECTRONICS S.p.a. reserves the right to make amendments at any moment and without notice. - 48 -...
  • Page 49 All manuals and user guides at all-guides.com Système de qualité certifié ISO 9001:2008 Curtarolo (Padova) Italy www.avselectronics.com OUTSPIDER PA Détecteur à double infrarouge passif pour usage interne et externe OUTSPIDER DT Détecteur à hyperfréquence à double infrarouge passif pour usage interne et externe IST0777V2.0...
  • Page 50 Gestion des paramètres ............... 65 CARACTÉRISTIQUES GÉNÉRALES ............ 52 Écran OutSpider DT ................65 Première alimentation : ..............52 Écran OutSpider PA ................65 Préliminaires : ..................52 Enregistrement : ................65 Description du fonctionnement du détecteur en modalité “réglage Fonction oscilloscope ................
  • Page 51 All manuals and user guides at all-guides.com Accessoires ACCESSOIRES FOURNIS ROTULE composée de : A. étrier coté mur B. rotule intermédiaire C. rotule coté détecteur D. Vis TC-C M6 INOX E. Écrou M6 INOX F. Rondelle dentée SABOTAGE composée de : A.
  • Page 52 NB : là où non précisé de manière explicite, les instructions se rapportent à tous les modèles. Première alimentation : À la première alimentation, OUTSPIDER PA et OUTSPIDER DT sont inhibés pendant 60 secondes environ, temps durant lequel les leds jaune et rouges sont activés ; ils clignotent alternativement et le buzzer émet un son intermittent.
  • Page 53 All manuals and user guides at all-guides.com Description du fonctionnement du détecteur en modalité “réglage d’usine”. Dans cette modalité, la section infrarouge sélectionne les alarmes en opérant les contrôles suivants : • Amplitude et symétrie du signal : la forme d’onde doit être supérieure aux seuils minimaux tant vers le positif que vers le négatif ; par ailleurs, la largeur des demi-ondes doivent être proportionnelles.
  • Page 54 All manuals and user guides at all-guides.com Couverture Éviter que dans le champ de révélation des détecteurs, des objets qui couvrent le champ de lecture ou que des plantes qui ne modifient l’environnement proche ne soient mètres présents. (max.) 2,2 mètres (max.
  • Page 55 All manuals and user guides at all-guides.com Ouverture détecteur et déplacement de la carte Installation de la plaque sur un mur ou sur un poteau Pour enl ev er le couvercle, soulever avant Perforations pour la la partie inférieure (1) puis fixation de la plaque sur le décrocher du guide paroi.
  • Page 56 All manuals and user guides at all-guides.com Installation antiarrachage Fixation de la base de la plaque Prédisposition pour l’accès des fils de connexion Avec rotule Accrocher la base du détecteur aux 2 points de blocage sur la partie inférieure de la plaque Point de fixation métallique.
  • Page 57 All manuals and user guides at all-guides.com Fixation carte Changement de la lentille Retirer les 6 vis de blocage Extraire le support de la lentille Insérer la carte en faisant se rencontrer les encoches A avec les point de blocages B Décrocher la lentille du support en faisant une légère pression sur les 4 blocages latéraux.
  • Page 58 Mode ORDINATEUR et activation BUS (SW2 : DIP1- sur un positif. Dans cette condition, le détecteur se comporte comme suit : OUTSPIDER PA: La programmation peut se faire par ordinateur, grâce au • Le relais d'alarme reste fermé logiciel HPWIN ou - en suivant une procédure spécifique –...
  • Page 59 All manuals and user guides at all-guides.com SW 1: voir page suivante SW2 - FONCTIONS Trimmer pour le réglage de la portée 1 2 3 4 5 6 7 8 ON connexion par DIP/Relais de l’hyperfréquence, OFF connexion par PC/BUS 1 2 3 4 5 6 7 8 augmente dans le...
  • Page 60 All manuals and user guides at all-guides.com SW1 - FONC TIONS Les DIP SWITCH du banc SW 1 Avec le fonctionnement à relais, les configurations programmables avec le banc de dip-sw itch SW1 sont : changent la fonction d’usage selon les modalités de fonctionnement réglé...
  • Page 61 Détecteur DIP1 DIP2 DIP3 DIP4 DIP5 OutSpider PA et OutSpider DT sont munis d’un circuit antimasquage, formé par un récepteur RX central et 4 émetteurs TX à infrarouge actifs positionnés sur les cotés des détecteurs PIR, qui détectent les obstacles placés en face du détecteur jusqu’à...
  • Page 62 All manuals and user guides at all-guides.com Fonctions spéciales Grace au logiciel pour ordinateur HPWIN, il est possible d’utiliser au mieux la potentialité de la technologie digitale. HPWIN permet pour chaque détecteur : Vérification: • Graphique signal des 2 infrarouges (sélectionnable) Retour au menu principal •...
  • Page 63 All manuals and user guides at all-guides.com Typologie de connexion pour la gestion avec logiciel HPWIN Le détecteur peut être connecté à l’ordinateur par : • Connexion série RS232 (non utilisé) • Connexion USB • Ligne téléphonique (Modem) Connexion USB Ce type de connexion permet la connexion du détecteur à...
  • Page 64 All manuals and user guides at all-guides.com Gestion détecteurs L’accès à ce menu impose le choix d’un type de connexion. 1. Suivre la procédure selon le type de connexion à effectuer. NB : s’il s’agit d’une connexion en USB, il sera peut être demandé l’installation des drivers pour la reconnaissance du périphérique. Si les drivers ne sont pas reconnus automatiquement, il est nécessaire de spécifier au système opératif le parcours suivant : C:\Programmes\Xwin\Driver\ et de sélectionner le fichier stmcdcAVS.inf.
  • Page 65 % sensibilité hyperfréquence : réglage de la sensibilité de l’hyperfréquence (par le logiciel, il n’est possible que de diminuer par rapport à la valeur décidée par le trimmer RV1 du détecteur). Écran OutSpider PA Sensibilité OutSpider DT : sélectionner la sensibilité de la section infrarouge On/Off antimasquage : gestion de la fonction antimasquage Mémoire alarme toujours : mémorise toutes les alarmes ou uniquement celles lorsque le...
  • Page 66 Ligne verte (V) : indique le signal du circuit antimasquage NB : OutSpider PA, pour cacher le signal de l’Infrarouge inférieur , il est nécessaire de retirer le pointage tant de la partie Rouge que le la partie Jaune (G), tandis que pour cacher le signal de l’infrarouge supérieur , il suffit d’enlever le signe sur l’emplacement Blanc (B).
  • Page 67 All manuals and user guides at all-guides.com Œ Les signaux détectés par les 2 infrarouges ne correspondent pas. La section Œ • Ž infrarouge indique l’alarme uniquement si le signal dépasse un certain seuil et si le détecteur est réglé sur la configuration HAUTE. •...
  • Page 68 OutSpider DT OutSpider PA • Tension d’alimentation • Température dans le détecteur • État du détecteur : OUTSPIDER PA : sabotage – alarme – antimasque OUTSPIDER DT : sabotage – alarme générale – antimasque – alarme section hyperfréquence. - 68 -...
  • Page 69 All manuals and user guides at all-guides.com Librairie des signaux L’accès à ce menu impose le choix du type de connexion : 1. Suivre la procédure en fonction du type de connexion à effectuer. NB : s’il s’agit d’une connexion en USB, il sera peut être demandé l’installation des drivers pour la reconnaissance du périphérique. Si les drivers ne sont pas reconnus automatiquement, il est nécessaire de spécifier au système opératif le parcours suivant : C:\Programmes\Xwin\Driver\ et de sélectionner le fichier stmcdcAVS.inf.
  • Page 70 All manuals and user guides at all-guides.com Archives • L’archive des enregistrements permet de visualiser les signaux enregistrés par l’installateur sur l’ordinateur, avec la procédure d’ « enregistrement » décrite dans le chapitre « gestion détecteurs » Œ En entrant dans cette archive, on accède à une base de donnée où les différents fichiers sont sauvés avec date et heure, description et durée de l’enregistrement.
  • Page 71 Directive 1999/5/CEE (R&TTE) sur les appareils radio- émetteurs de faible puissance et sur l’utilisation des fréquences de spectres radioélectrique, en accord avec la recommandation CEPT 70-03 Marque AVS ELECTRONICS Modèle OUTSPIDER DT Fréquence de travail 10,525 Ghz Courant continu Type d’alimentation...
  • Page 72 Acoustique : buzzer caractéristiques d’une source à puissance limitée protégée par fusible. Lentilles couverture infrarouge Degré de protection IP 65 IP 65 AVS ELECTRONICS S.P.A. se réserve le droit d’apporter des modifications à n’importe quel moment et sans préavis. - 72 -...

Ce manuel est également adapté pour:

Outspider dt