Sensor operation
The detector can be connected in DIP/RELE' mode or in
PC/BUS mode:
DIP/RELE' Mode (SW2:DIP1-ON):
The programming occurs via the two sets of dip-switches
which are on board:
In this working mode:
-
the relay and O.C. outputs are active
-
the RS485 derial is not active
-
the USB connexction is active
-
the HPWIN software only allows the visualization
(and not the programming) of the detector status.
-
The connection of the detector occurs exclusively
E
using the relays and outputs on board.
N
PC mode and BUS activation (SW2: DIP1-OFF):
G
The programming can occur by PC via the HPWIN
software or via the Dip mode following a special procedu-
re.
In the PC mode, although previously set in the detector
by the DIP-SWITCH, the configuration can be modified
using the HPWIN program.
In this working mode:
- The relay and O.C. outputs are active
- The RS485 serial is active
- The USB connection is active
- The HPWIN software allows the entire management
of the detector
- The connection of the detector occurs by using the
RS485 serial or the relays on board.
Only management of the LEDs and the AUX clamp
cannot be modified through the PC, but only using
the related DIP SWITCHES (1 - 2 - 3 - 4 - 5 - 6 and
8 of the SW 2).
All manuals and user guides at all-guides.com
TERMINAL BOARD
+
Power supply positive pole 12 V
Serial RS485:
DA
When operating with DIP/Relay the serial is disabled.
DB
When operating with PC/BUS, to be connected to input of XSATHP satellites or directly
to serial 485 of pre-set control panels
-
Power supply negative pole 12 V
C
Alarm signal output. Contact C - N.C. controlled by microprocessor.
NC
T
Anti-tampering signal output. Contact C - N.C. controlled by microprocessor.
T
AM
Anti-mask signal output. Contact C - N.C. controlled by microprocessor.
AM
B
Input enabling sensor to have reference of status of control panel. To manage this
information, when the control panel is off, this input must be closed to positive pole.
In this condition, act as follows:
OUTSPIDER PA:
• the alarm relay remains closed
• if an alarm is generated, the LED and buzzer are activated.
OUTSPIDER DT :
• the alarm relay remains closed
• The microwave power is cut (only if the HPWIN software sets the step "Always memorise
alarm" at ON, the microwave continues working regularly)
• if an alarm is generated, the LED and buzzer are not activated (only if the HPWIN software
sets the step "Always memorise alarm" at ON or the "Security" mode is set, the LEDs
activate)
F
Dirty Lenses Failure signal output. This terminal supplies a transistorised negative pole if
an increase of the reflected signal, prolonged in time, is detected by anti-mask circuit.
AUX
With the DIP SWITCH 6 ON, the offset of this input activates the Alarm relay.
With DIP SWITCH 6 OFF, the offset of this input activates the T amper relay (to be used for
the anti-tamper circuit connection).
AUX is an input with reference to negative.
- 34 -