SW1 - SENSOR ADDRESS
Sensor
DIP1 DIP2 DIP3 DIP4 DIP5
1
ON
ON
ON
2
OFF
ON
ON
3
ON
OFF
ON
4
OFF
OFF
ON
5
ON
ON
OFF
6
OFF
ON
OFF
7
ON
OFF
OFF
8
OFF
OFF
OFF
9
ON
ON
ON
10
OFF
ON
ON
11
ON
OFF
ON
12
OFF
OFF
ON
13
ON
ON
OFF
14
OFF
ON
OFF
15
ON
OFF
OFF
16
OFF
OFF
OFF
17
ON
ON
ON
18
OFF
ON
ON
19
ON
OFF
ON
20
OFF
OFF
ON
21
ON
ON
OFF
22
OFF
ON
OFF
23
ON
OFF
OFF
24
OFF
OFF
OFF
25
ON
ON
ON
26
OFF
ON
ON
27
ON
OFF
ON
28
OFF
OFF
ON
29
ON
ON
OFF
30
OFF
ON
OFF
31
ON
OFF
OFF
32
OFF
OFF
OFF
N.B. Dip Switches 6, 7 and 8 are not used
NOTE: by default, the DIP SWITCHES are all
positioned at OFF
All manuals and user guides at all-guides.com
Antimask and Dirty Lenses
ON
ON
OutSpider PA and OutSpider DT are equipped with an anti-masking circuit, made of a central RX
ON
ON
receives and four active infrared TX transmitters positioned on the sides of the PIR sensors, that detects
ON
ON
obstacles placed in front of the sensor up to a distance of about 5 cm.
ON
ON
An alarm, caused by an attempt to mask the sensor, is signalled by quick flashing of the yellow sensor
ON
ON
and activates the dedicated relay output AM.
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
TX
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
TX
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Initial power-up
OFF
OFF
OFF
OFF
Upon initial power-up the anti-masking circuit completes a self-adjustment.
OFF
OFF
In this phase it is essential for the cover to be properly installed in order to allow the sensor to
OFF
OFF
adjust itself to the correct value.
OFF
OFF
OFF
OFF
Precautions
OFF
OFF
OFF
OFF
Keep the sensor lens clean from dust or other filtering material that may modify its operation.
Operation
Antimask: When the Antimask circuit detects an obstacle that is
less than 5 cm from the lenses, a delay time of about 20 seconds
TX
activates before this is signalled. If, at the end of this time, the
obstacle is not removed, the AM anti-masking relay activates
and the yellow LED flashes slowly.
Both the LED and the relay are automatically reset after the first
RX
alarm of the sensor.
NOTE: this function however does not guarantee that the sensor
cannot be masked.
Dirty lenses: When the Antimask circuit detects that the average
of the signal value saved after a certain interval of time changes
TX
by about 20 %, the F output and the yellow LED flashes slowly.
- 37 -