Télécharger Imprimer la page

Franke FSW 918 TC W BK XS-CH V2 Mode D'emploi Et Installation page 27

Publicité

Les langues disponibles

Les langues disponibles

This cannot be washed or regenerated, and must be changed when the F button LED on the
display starts to flash, or at least once every 4 months. The Alarm signal must be activated in
advance.
Activating the alarm signal
• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installa-
tion or at a later date.
• Turn the Lights and the Suction Motor off.
• Press F and hold for approximately 4 seconds, after which:
• The LEDS on buttons F and B flash twice: Activated Charcoal filter saturation alarm
ACTIVATED
• The LEDS on buttons F and B flash once: Activated Charcoal filter saturation alarm
DEACTIVATED
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• With the filter alarm on, press button F briefly (see the para-
graph on USE).
Changing the Filter
• If closed, open the door by pressing button H and holding for
approximately 2 seconds (see USE).
• Remove grease filters.
• Remove the saturated activated charcoal filters, as indicated
(A).
• Fit the new filters, as indicated (B).
• Replace the metal grease filters.
Cleaning the inside of the Hood
The inside of the hood must be cleaned regularly. To do this, pro-
ceed as follows:
• Open the Top Door (see USE).
• Open the Bottom Door by pulling it downwards with your
hands.
• Clean the inside of the Hood.
• Close the lower door again, checking that it has fastened
properly so that there is no risk of it opening accidentally.
EN
Activated Charcoal Filter (Recirculation Version)
A
B
2
27

Publicité

loading

Ce manuel est également adapté pour:

Fsw 918 tc w wh xs-ch v2