Inspection
Prior to EACH use, inspect SRL for deficiencies,
including, but not limited to, corrosion, deformation,
pits, burrs, rough surfaces, sharp edges, cracking,
rust, paint build-up, excessive heating, alteration,
broken stitching, fraying, and missing or illegible
labels. IMMEDIATELY remove harness from service
if defects or damage are found, or if exposed to
forces of fall arrest.
Inspect shock pack to determine if SRL has been
exposed to excessive forces. The white portion of
the tear webbing must not extend past shoulders
of shock pack as indicated below. If any portion of
white tear webbing extends outside of this area
the SRL has been exposed to excessive forces and
must be removed from service.
No White Webbing
Shock Pack
Shoulder
Shock Pack
Shoulder
CIRCLE-X
Remove from
Remove from
Service!
Service!
White Tear Webbing
Exposed
Exposed
OK for Use
Ensure that applicable work area is free of all
damage, including, but not limited to, debris,
rot, rust, decay, cracking, and hazardous
materials. Ensure that work area will support the
application-specific minimum loads set forth in
this manual. Work area MUST be stable.
At least every 12 months, a Competent Person
(CP) other than the user must inspect harness.
Inspections MUST be recorded in inspection
log in instruction manual and on equipment
inspection
grid
Person must sign their initials in the box
corresponding to the month and year the
inspection took place.
During inspection, consider all applications and
hazards the SRL has been subjected to.
Product lifetime is indefinite as long as it passes
pre-use and CP inspections.
This inspection log must be specific to one
harness. Separate inspection logs must be used
for each harness. All inspection records must be
made visible and available to all users at all times.
If equipment fails inspection it must be discarded
immediately.
8
label.