English
Labels
1
Class
2
Anchor above
or below dorsal
D-ring
CR3-EDGE
10 ft (3 m) Self-Retracting Lifeline
ANSI Z359.14-2021
|
OSHA 1926.502 & 1910.140
Suitable for
LEADING EDGE
Se puede utilizar en aplicaciones borde expuesto
2
Part #
Date of Manufacture
4200007
MM
|
YY
Read supplied instructions before using. Failure to follow instructions
may result in serious injury or death. Never modify product. This product is not repairable.
USE This device is only for use by one person as
INSPECTION Prior to each use, check locking (pull sharply to
a fall arrester. Only make connections directly to
test) and retraction function. Inspect for signs of deployment,
attachment point on safety harness. Guard against
defects or damage to housing, lifeline (inspect full length),
swing-fall by keeping lifeline vertically overhead.
connectors, or missing parts. Inspect impact indicator - see
Ensure that connection to anchorage is secured
instruction manual. Ensure presence and legibility of all labels.
properly before use. Avoid lifeline contact with sharp
Inspection by Competent Person required at least every 12
or abrasive edges and surfaces. May be used as a
months. Immediately remove from service in event of failed
component of a PFAS in HLL applications. Design,
inspection, or if unit is subjected to a fall.
installation, and utilization of HLLs must be supervised
Lifeline Material: Steel Cable
by a Qualified Person. Suitable for horizontal use.
User Weight Range (including tools and equipment):
Competent Person must calculate fall clearance
ANSI: 130-310 lb
prior to use; fall clearance calculations must include
Arrest Force: Max: 1,350 lb
considerations for swing fall. Clearance numbers
Min. Setback Distance from edge: 0" (LE)
specified based on lifeline installed vertically
Max. Arrest Distance - 100-310 lb: 3' (Non-LE*)
overhead and in-line with worker.
Min. Required Fall Clearance - 100-310 lb: 6' 6" (Non-LE*)
Inspection
Date
Max. Free Fall: 5'
Initials
Permitted Service Temperature: -40° to 130° F
*Non-LE = Anchor at or above dorsal D-ring height
Date of First Use
Type: SRL
DO NOT REMOVE
LABELS
guardianfall.com
White
C0 M0 Y0 K0
R255 G250 B250
#FFFFFF
PANTONE® Process Black
PANTONE® 7549
C0 M0 Y0 K0
C0 M32 Y100 K0
R0 G0 B0
R253 G181 B21
#000000
#FCB414
Lot #
Serial #
Label Stock:
MacTac REBEL 4MIL MATTE PVC HT PRINT RB528H
Laminate:
MacTac PERMAFLEX 5MIL LUSTRE CLEAR PVC PERM LAM PF6315
|
Length: 10'
|
OSHA: 100-310 lb (LE)
|
OSHA: 100-420 lb (Non-LE*)
|
Avg: 1,150 lb
|
8' 6" (LE)
311-420 lb: 3' (Non-LE*)
|
17' (LE)
Tested in the USA.
1
Class 2
Anchor above or below dorsal D-ring
CR3-EDGE
Self-Retracting Lifeline
ANSI Z359.14-2021 | OSHA 1926.502 & 1910.140
Suitable for leading edge use
Part #
Date of Manufacture
4200007
MM
2
Read supplied instructions before using. Failure to follow instructions
may result in serious injury or death. Never modify product. This product is not repairable.
USE This device is only for use by one person as
a fall arrester. Only make connections directly to
Part # | Date of Manufacture: | Lot # | Serial #
attachment point on safety harness. Guard against
swing-fall by keeping lifeline vertically overhead.
Ensure that connection to anchorage is secured
WARNING Read supplied instructions before using. Failure to
properly before use. Avoid lifeline contact with sharp
or abrasive edges and surfaces. May be used as a
component of a PFAS in HLL applications. Design,
follow instructions may result in serious injury or death. Never
installation, and utilization of HLLs must be supervised
by a Qualified Person. Suitable for horizontal use.
modify product. This product is not repairable.
Competent Person must calculate fall clearance
prior to use; fall clearance calculations must include
considerations for swing fall. Clearance numbers
specified based on lifeline installed vertically
USE This device is only for use by one person as a fall arrester.
overhead and in-line with worker.
Only make connections directly to attachment point on safety
Inspection
Date
harness. Guard against swing-fall by keeping lifeline vertically
Initials
Date of First Use
overhead. Ensure that connection to anchorage is secured
Type: SRL
properly before use. Avoid lifeline contact with sharp or abrasive
DO NOT REMOVE
LABELS
edges and surfaces. May be used as a component of a PFAS
in HLL applications. Design, installation, and utilization of HLLs
must be supervised by a Qualified Person. Suitable for horizontal
use. Competent Person must calculate fall clearance prior to
use; fall clearance calculations must include considerations
for swing fall. Clearance numbers specified based on lifeline
installed vertically overhead and in-line with worker.
White
INSPECTION Prior to each use, check locking (pull sharply to
C0 M0 Y0 K0
R255 G250 B250
test) and retraction function. Inspect for signs of deployment,
#FFFFFF
defects or damage to housing, lifeline (inspect full length),
connectors, or missing parts. Inspect impact indicator - see
instruction manual. Ensure presence and legibility of all labels.
Inspection by Competent Person required at least every 12
months. Immediately remove from service in event of failed
inspection, or if unit is subjected to a fall.
Lifeline Material: Steel Cable | Length: 10'
User Weight Range (including tools and equipment):
ANSI: 130-310 lb | OSHA: 100-310 lb (LE) |
OSHA: 100-420 lb (Non-LE*)
Arresting Force: Max: 1,350 lb | Avg: 1,150 lb
Min. Setback Distance from edge: 0" (LE)
Max. Arrest Distance:
100-310 lb: 3' (Non-LE*) | 8' 6" (LE)
311-420 lb: 3' (Non-LE*)
Min. Required Fall Clearance:
100-310 lb: 6' 6" (Non-LE*) | 17' (LE)
Max. Free Fall: 5'
Permitted Service Temperature: -40° to 130° F
*Non-LE = Anchor at or above dorsal D-ring height.
Type: SRL
Do Not Remove Labels
Tested in the USA.
6
Lot #
Serial #
|
YY
INSPECTION Prior to each use, check locking (pull sharply to
test) and retraction function. Inspect for signs of deployment,
defects or damage to housing, lifeline (inspect full length),
connectors, or missing parts. Inspect impact indicator - see
instruction manual. Ensure presence and legibility of all labels.
Inspection by Competent Person required at least every 12
months. Immediately remove from service in event of failed
inspection, or if unit is subjected to a fall.
Lifeline Material: Steel Cable
|
Length: 10'
User Weight Range (including tools and equipment):
ANSI: 130-310 lb
|
OSHA: 100-310 lb (LE)
|
OSHA: 100-420 lb (Non-LE*)
Arrest Force: Max: 1,350 lb
|
Avg: 1,150 lb
Min. Setback Distance from edge: 0" (LE)
Max. Arrest Distance - 100-310 lb: 3' (Non-LE*)
|
8' 6" (LE)
311-420 lb: 3' (Non-LE*)
Min. Required Fall Clearance - 100-310 lb: 6' 6" (Non-LE*)
|
17' (LE)
Max. Free Fall: 5'
Permitted Service Temperature: -40° to 130° F
*Non-LE = Anchor at or above dorsal D-ring height
Tested in the USA.