Télécharger Imprimer la page

Emerson InSinkErator involve Serie Manuel Du Propriétaire page 6

Publicité

Les langues disponibles

Les langues disponibles

5
fInal wateR cOnnectIOn
Brass Nut
Ferrule
Brass Insert
a
Brass
nut
Copper
Brass
ferrule
tube
Insert
3/8"
Plastic
tube
Property Damage: Join remaining tube
to cold water supply only.
a
Brass
nut
ferrule
1/4"
copper
tube
Property Damage: Join remaining tube
to cold water supply only.
6
fIll tanK & then cOnnect POweR
Brass Nut
Brass Nut
Ferrule
a
Ferrule
Brass Insert
c
Copper
tube
Scalding Hazard: The faucet dispenses
near-boiling (212ºF) water which can
instantly cause scalds or burns. Use care
when operating this appliance.
b
Electric Shock Hazard: A standard grounded
outlet within 30" of the dispenser is required
under the sink. Do not use an extension
cord set with the dispenser.
10
Fiber
HC-View/HC-Wave
Install a t-fitting (not included) onto the
cold water supply line.
Install dedicated water control valve with
3/8" compression fitting.
at the end of the white 3/8" tube from
the quick-connector, slide the supplied
brass nut and ferrule over the tube and
then push in the brass tube insert.
Insert the white 3/8" tube into the 3/8"
compression fitting and tighten.
H-View/H -Wave/H990/H770
Install a t-fitting (not included) onto the
cold water supply line.
Install dedicated water control valve with
1/4" compression fitting (not included).
at the end of the copper 1/4" tube,
slide the brass nut and ferrule provided
with the control valve over the tube.
Insert the copper tube into the 1/4"
compression fitting and tighten.
turn on the cold water supply.
Depress the dispenser's HOT
handle and hold it until water flows from
the spout (approximately 1 to
2 minutes).
Run the water for at least 2 minutes to
flush lines (both the hot and cold handles
independently if applicable).
check all connections to ensure they are
tight and that there are no leaks.
Plug in instant hot water tank.
Water will be cold at first.
Allow 12-15 minutes for water to reach
target temperature.
Gurgling or hissing is normal during the
initial heating cycle.
Electric Shock Hazard: Using an ungrounded or improperly connected
appliance can result in serious injury or death from electrical shock.
This appliance must be grounded. This instant hot water dispenser is equipped with a cord that has a
grounding conductor and a grounding pin. The plug must be connected to an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances. Do not modify the plug provided
with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Check
with a qualified electrician or serviceman if you are in doubt as to whether the instant hot water dispenser is
properly grounded.
Personal Injury: This tank is a non-pressurized tank. DO NOT modify this system.
DO NOT close vent tube or connect other type dispensers or valves to the tank. Use
only the InSinkErator dispenser faucet supplied. Use only parts provided. Contact an
authorized InSinkErator Service agent for repairs or replacement components.
Fire Hazard: To minimize possibility of fire, DO NOT store flammable items such as
rags, paper or aerosol cans near the tank. DO NOT store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
Property Damage: To avoid water damage, replace any loose or split tubing.
Periodically inspect the unit for any signs of leakage and immediately remove from
service any unit suspected of leaking.
An instant hot water dispenser, like any water heater, has a limited life and will eventually
fail. To avoid possible property damage and personal injury, this instant hot water dispenser
should be regularly examined for leakage and/or corrosion and replaced when necessary.
A drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should be
used in those applications where any leakage could cause property damage. To check
for corrosion, examine the appearance of the dispensed water in a clear glass once every
three (3) months. If there is any discoloration or rusty appearance, unplug and drain unit as
described in the Seasonal Storage/Drainage section on page 13 of this manual. If the water
discoloration remains after draining and refilling unit, discontinue use and contact an
authorized InSinkErator service agent.