Télécharger Imprimer la page

Weka 511.2020.11.00E Notice De Montage, D'utilisation Et D'entretien page 7

Publicité

Assembly recommendations
Please drill pilot holes for all screw connections to avoid
damaging the wood. The following symbol in the
instructions will indicate when this is necessary:
General assembly of the wall elements
Figure shows a cross-section through a wall
section with profile wood boarding on both sides.
All wall elements are equipped with a vapour
barrier and heat insulation. After assembly of
the sauna, the vapour barrier must always be
located directly behind the interior boarding.
The inner side of the wall element is
indicated on the wooden frame by the
following stamp
innen → .
inside = innen
Before erecting the individual elements, take
care to ensure that the groove side
(viewed from outside) is always on the left.
Mounting timber has been incorporated into the
wall elements for the bench mountings.
These are located approx. 36 cm and 80 cm above
the floor. The location of this timber can be seen
at the visible screw heads in the element frames.
Each time you install a wall element, ensure that
these screw heads are located in the lower half of
the element.
Preparing the wall panel for installation of the multi-function control system
For installation of the control unit,
the opening height in the wall panel
must be 10 cm.
To attain this height, push the loose
sheathing board and the plastic pipes
upward and out and shorten the
board and pipes accordingly.
NOTE: It is absolutely necessary
that this be carried out
BEFORE the wall panel is set up.
R1-R5: These serve as assembly tubing
for the mains connection electric cable,
the sauna lamp and the sauna furnace
ending at the control unit.
R1 + R4:
for running cable from oven
control system module to the
sauna oven
R2:
for running cable from oven
control system modul to the
control unit
R3 + R5:
reserve
Technische. Änderungen vorbehalten!
Alle Maße sind ca. Maße!
6
© Copyright HRB 3662

Publicité

loading