I.
II. II.
1.
2.
3.
4.
GB
I.
Description
1
Wall mount
1
2
Luminaire
3
Power cable
4
Angle fixing screw
5
Connection terminal
2
6
Screw cap
7
PIR motion detector
8
Sensor fixing screw
3
4
5
6
7
8
II.
Assembly
1.
Select an installation location without pipes or cables behind it. Mark the fastening holes,
and drill the holes for the clamps. Ensure that these are positioned according to the fix-
ing slots in the wall mount 1.
2.
Insert the plugs, and fix the luminaire 2 with the screws.
Caution: Make sure the fasteners are suitable for the wall material.
3.
To change the angle of the luminaire slightly loosen the mount fixing screws.
4.
Adjust the luminaire 2 in the desired angle. If necessary, loosen the angle fixing screws 4 and
tighten them again.
5.
Connect the luminaire 2 to the power supply (see section III).
6.
Set the motion detector (see section IV).
36
36
ENGLISH
ENGLISH
III.
Connection
Caution:
First disconnect the power supply for this connection.
1.
Disassemble the connection terminal 5. Remove 8 mm of insulation from each cable.
Push cable through the cable inlet and connect the luminaire 2 to the power supply
(see figure).
2.
Fix the cables by tightening the screws. Make sure that the connections are tight and
that no loose cable endings emerge from the terminal.
N: Blue
L: Brown
: Yellow/Green
3.
Reassemble the connection terminal 5 and tighten the screw cap 6 with 10 Nm.
Make sure the cable insulation reaches well within the connection terminal.
Connect the power supply.
IV.
PIR motion detector
1.
Adjust the settings of their motion detector 7 by rotating the corresponding dials:
1.
TIME: Change the lighting time from 10 s to 10 min.
2.
LUX: Define the ambient luminance level below which the lamp is activated (day / night).
The luminaire turns on automatically when movement is detected in the sensing area
and the ambient luminance is below the adjusted level. It will stay lighted for 10 s -
10 min, depending on the settings. High temperatures or strong light interference could
cause malfunctions.
V.
Maintenance and care
Cleaning
Wipe the luminaire with a soft, damp cloth only. Never use scouring powders or chemi-
cal cleaning agents. Never allow the electrical components to become damp.
GB
1.
8 mm
15 mm
2.
3.
1.
2.
37
37
III. III.
IV.
V.