8 - INSTALLATION INFORMATION AND INSTRUCTIONS
FOR DRAIN COUPLING, DRAIN-BOA
When installing,
center clamps in
the clamp groove
at all three ports.
Preferred coupling
loction - above
trap inlet nut.
Rotate coupling as needed before clamping.
This coupling depicted before the clamps are installed.
(If large stainless screw drive clamps are used (ref.
Fig.6), their width must be 0.50" (preferred).
3/8" or 1/2" O.D. Polyethylene tubing from air gap
unit or air gap dispensing faucet.
Coupling upstream end
DRAIN-BOA™
MODEL DC9700
UPC® NSF®
MADE IN U.S.A.
Coupling downstream
end
1.675 (4.25cm)
Depicts certain dimensions and marking cut 3/8"
or 1/2" poly tubing square and wet only with water
before inserting to "stop".
(Above Fig. shows partial cutaway of inlet port for
illustration purposes. Nylon rod, ball and seat (kit DC97)
may be a possible option later).
All manuals and user guides at all-guides.com
Minimum
overlap at each
end approx.
0.70" (1.78cm).
Cut (B)
2"
This allows at
least 1" above
inlet nut for
removal and
possible trap
replacement if
ever needed.
Fig.5
An option not normally used
but if 1/8" dia. nylon rod is
used, carefully drill 3/32" hole
only thru this pilot hole. (NOT
both sides).
Push tunnel shape end of part
(97001) into tubing, leaving
seat end exposed about 0.1"
(0.25cm).
Seat
Funnel
shape
end
Insert tubing to
shoulder "stop"
inside inlet port
3/16" dia. ball here
(Plastic or rubber)
3/8" O.D. tubing
1/4" O.D.
P.E. tubing
Tubing flush on this end
(creating a stap up
bushing)
Fig.7
TM
MODEL DC9700
Generally there
is very little
water pressure
inside the
coupling. With
full sink only
about 24"
(61cm) water
height above
coupling.
Fig.6
Depicts Drain-BOA™ coupling installed with stainless
steel screwdrive clamps on the large ports.
(Either tubing or solid plug (97002) must be installed at
all times, otherwise leakage will occur out this port).
Air Gap unit or Air Gap faucet
Sink
Drain
tubing
1.50" (3.8cm)
Horizontal
sink tailpiece
1.50"
drainage pipe
Preferred coupling
location but existing
spacing too close
to allow installation
of coupling here.
Fig.8
Depicts Drain-BOA™ coupling installed in a horizontal
branch below kitchen sink, due to space limitations at
the preferred installation site.
(Always install unit according to flow arrows).
88
If metal
clamps are to
be used, do
not over
torque screw
drive clamps -
just snug with
screw driver
Included special
plug (97002) must be
clamped as shown
at all times except
when tubing is used.
Insert plug only to
the stop ring. If not
used, tape plug to
back of coupling for
future use if needed.
Remove small clamp
first, to remove plug or
tubing.
Drain tubing
from (RO)
drinkking
water
system
Port on
top side
*If necessary to
install as shown, then
side inlet port to be on
top side of drainage
pipe or side port can
be rotated apporx. 45"
in either direction as
best dictated by each
installation site.