Control and connection panel
4
2
5
1 IN: balanced input, with adjustable sensitivity (microphone
-40dB / 2kOhms or line 0dB / 20kOhms), fitted with a Neutrik
Combo
connector which accepts both 3 pin XLR and jack plugs.
®
☛ See 'connectors' and 'connections' at pages 36 and 37,
and 'applications at pages 38, 39, 40.
2 LINE/MIC: input sensitivity switch (mic when pushed in).
To prevent unwanted operation, this control is recessed within the
panel, and it must be operated using a suitable tool, such as a pen
or a screw driver.
The switch is factory set in the 'line' position (button up) for the
most common applications (connection to a mixer or to other
active systems). If you want to connect a microphone directly to the
input you must push the button to 'mic' (as input and output of the
W440A are connected in parallel and carry the same signal, should
the output be connected to another W440A the line/mic switch of
the latter should also be set in the same way of the other).
3 OUT: balanced output, (in parallel with the input), using a 3 pin
XLR connector. It allows for easy parallel connection of other
W440A or active systems.
☛ See 'connectors' and 'connections' at pages 36 and 37,
and 'applications at pages 38, 39, 40.
4 GAIN: input level control. It is the master volume control.
It also allows to adjust the speaker volume when this system is used
in parallel with others. Typical operating setting is on maximum
position. When a microphone is connected to the input this control
must be adjusted to reach the desired volume.
The trademark Neutrik Combo
®
is property of Neutrik
All manuals and user guides at all-guides.com
active, processor controlled, bi-amped speaker system
1
5 Bass / Mid / High: 3-band equalizer. It allows changing the
response curve of the system depending on the requirements of
each different application. This enables optimizing the W440A's
working condition for each specific requirement whether it is used
for example in a conference hall, on stage for monitoring and
many other situations.
☛ See examples of settings at pages 12 and 13.
6 Mains power on/off switch.
7 Mains power cord socket (with built-in fuse).
Use only the factory supplied mains cable or a suitable cable with
a ground connection and marked with the safety approvals valid
in the country of use.
When installing make sure that it is easy to get to this connector
and to the mains plug.
6
3
7
W440A
FUSE REPLACEMENT
Service fuse
Spare fuse
11