28
www.aeg.com
Problem
Door does not open easily.
If the advice does not lead
to the desired result, call the
nearest Authorized Service
Centre.
8.2 Replacing the lamp
The appliance is equipped
with a long-life LED interior
light.
It is strongly recommended
to use original spare parts
only.
Use LED bulbs (E14 base)
only. The maximum power is
shown on the lamp unit.
CAUTION!
Disconnect the plug from
the mains socket.
1. Using a screwdriver, remove the
screw from the lamp cover.
2. Detach the lamp cover in the
direction of the arrows.
Possible cause
The appliance is fully loaded
and is set to the lowest tem-
perature.
You attempted to re-open
the door immediately after
closing.
3. Replace the lamp with the one that
has identical characteristics and is
specifically designed for household
appliances.
4. Reassemble the lamp cover.
5. Tighten the screw to the lamp cover.
6. Connect the plug to the mains
socket.
7. Open the door.
Make sure that the light switches on.
8.3 Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to
assembly instructions.
3. If necessary, replace the defective
door gaskets. Contact the Authorised
Service Centre.
Solution
Set the temperature regula-
tor to a higher temperature
to allow automatic defrost-
ing.
Wait a few seconds between
closing and re-opening of
the door.