SECTION 5: HOW TO USE
Type of radiators can be used for this ventilator:
≥
1. Wide radiator
69mm
2. Narrow radiator < 69mm
3. Single sided radiator
4. Convector
5. Other radiators
5.1
Connect the ventilator to a wide radiator (plates ≥ 69 mm apart)
1. Make sure that the ventilator (A) faces upwards, put it between the radiator plates and the magnets
will automatically stick to the radiator.
2. Identify a space where the radiator wall brackets and connecting clips are not in the way. Attach
the ventilator (A) at the bottom between the radiator plates with the adjustable magnets. The
ventilator (A) can also be attached on top of the radiator and under a cover. NOTICE Make sure the
fans still face upwards!
3. Connect the thermostat cable (C) and temperature sensor (E) to one of the ventilator (A) type C
connectors . Make sure the thermostat cable (C) and temperature sensor cable (E) are connected
to the Type C ports on the ventilator at the same side.
4. Attach the temperature sensor (C) with its adjustable magnets on the back of the radiator, close to
the heated water supply pipe, or on the pipe itself.