Maximum Holding Force
Hydraulic Operating Pressure
WFC / WSC 72
7,78 (1750)
6,67 (1500)
5,56 (1250)
4,45 (1000)
3,34 (750)
2,22 (500)
1,11 (250)
70
140
0
(1000)
(2000)
Operating Pressure
bar (psi)
Maximum Holding Force
Hydraulic Operating Pressure
WFC / WSC 112
11,12 (2500)
8,90 (2000)
6,67 (1500)
4,45 (1000)
2,22 (500)
70
140
0
(1000)
(2000)
Operating Pressure
bar (psi)
Maximum Holding Force
Hydraulic Operating Pressure
WFC 222 / WSC 222
22,3 (5000)
17,8 (4000)
13,4 (3000)
8,90 (2000)
4,45 (1000)
0
70
140
(1000)
(2000)
Operating Pressure
bar (psi)
SPECIFICATIONS TABLE
vs.
210
280
350
(3000)
(4000)
(5000)
vs.
280
350
210
(4000)
(5000)
(3000)
vs.
210
280
350
(3000)
(4000)
(5000)
3 3
Support Plunger Deflection
Applied Load
at 350 bar (5000 psi)
Operating Pressure
WFC / WSC 72
.0030 (0,076)
.0025 (0,064)
.0020 (0,051)
.0015 (0,038)
.0010 (0,025)
.0005 (0,013)
0
400
800
(1,78)
(3,56)
Applied Load
Support Plunger Deflection
Applied Load
at 350 bar (5000 psi)
Operating Pressure
WFC / WSC 112
.0030 (0,076)
.0025 (0,064)
.0020 (0,051)
.0015 (0,038)
.0010 (0,025)
.0005 (0,013)
0
500
1000
(2,22)
(4,45)
Applied Load
Support Plunger Deflection
Applied Load
at 5000 psi (350 bar)
Operating Pressure
WFC 222 / WSC 222
.0030 (0,076)
.0025 (0,064)
.0020 (0,051)
.0015 (0,038)
.0010 (0,025)
.0005 (0,013)
0
1,000
2,000
(4,5)
(8,9)
Applied Load
vs.
1200
1600
2000
(5,34)
(7,12)
(8,90)
kN (lbs.)
vs.
1500
2000
2500
(6,67)
(8,90)
(11,12)
kN (lbs.)
vs.
3,000
4,000
5,000
(13,4)
(17,8)
(22,3)
kN (lbs.)