Safety
Check especially the prescribed electronic test according to VDE function test to minimize unplanned
malfunctions and major consequential damage.
Effort
The maintenance costs of a system depend on, among other things, it's age, running time, load, and
installation type of the system. Because the time required can also vary from one maintenance interval
to the next, maintenance is usually calculated on a flat-rate basis. Replacement of necessary compon-
ents or wear parts are charged according to time and effort.
Intervals:
The intervals must not be greater than:
/
1/4 year for systems in commercial establishments
/
1/2 year for systems in apartment buildings
/
1 year for systems in single-family houses.
Warranty:
In order for the operator to be able to make use of any warranty claims in accordance with VOB or
DIN a maintenance contract must be concluded after acceptance of the new system. Please note that
for a warranty claim, corresponding evidence of the maintenance work carried out must be submitted.
11.
Accessories
11.1
Plug-in alarm kit FLOWBOXSAFETYKIT
Acoustic alarm with signalling unit for plugging in to a 230 V DIN socket, with integral 230
V earthed DIN socket into which the washing machine is plugged (l max. 16 A).
Potential-free contacts, once as NO contact, and once as NC contact, usable as fault
signalling contact (I max.12 A/V max. 250V), e.g. for building control system or to switch
off another device in the inlet. Optional rechargeable accumulators for mains-independent
alarm signal, including 5 m cable for connection to the FLOWBOX-N.
KBN: FLOWBOXSAFEKIT
11.2
CONEL rechargeable battery for alarm system
Rechargeable battery to change the CONEL alarm system for network-independent
operation.
KBN: ABSBATT9
11.3
ABS front wall installation set
Required for installation of lifting system behind a front wall, if ventilation via the roof
through an independent vent line is not possible/economical. This set contains all required
parts to install the breather and vent with active charcoal filter on the front wall.
KBN: ABSVIS
37