Display readout below min.- / above max. (-1999, 9999):
Input
Range
All
All
Sensor error detection limits:
Sensor error detection (SE.BR, SE.SH):
Input
Range
CURR
Loop break (4..20 mA)
POTM
All, SE.BR on all 3-wire
Ω
0...800
LIN.R
0...10 kΩ
TC
TEMP
RTD, 2-, 3-, and 4-wire
No SE.SH for Pt10, Pt20 and Pt50
Error indications:
Readout at hardware error
Error search
Test of internal CJC sensor
Checksum test of the setup in FLASH
Check measurement of analogue output current
Communications test PGMMOD00 / device
Check that input signal matches input setup
Check that saved setup in PGMMOD00 matches device
! Error indications in the display flash once per second. The help text explains the error.
1) The error is reset by switching off and then switching on the supply voltage to the device.
14
All manuals and user guides at all-guides.com
Readout
Limit
-1999
Display readout <-1999
9999
Display readout >9999
Readout
Limit
SE.BR
<= 3.6 mA; > = 21 mA
Ω
SE.BR
> ca. 126 k
Ω
SE.BR
> ca. 875
Ω
SE.BR
> ca. 11 k
Ω
SE.BR
> ca. 750 k
/ (1.25 V)
Ω
SE.BR
> ca. 15 k
Ω
SE.SH
< ca. 15
Readout
Error cause
CJC sensor defect or tem-
CJ.ER
perature outside range
FL.ER
Error in FLASH
1) No load on the current
AO.ER
output (only 4...20 mA)
NO.CO
Connection error
IN.ER
1) Error levels on input
TY.ER
Setup mismatch
CONNECTIONS
Supply:
31
32
33
Inputs:
RTD, 2-wire
RTD, 3- / 4-wire
43
43
41
42
44
41 42
44
Resistance,
Potentiometer
3- / 4-wire
41 42
43
44
41 42
43
44
Voltage
41 42
43
44
-
+
Outputs:
Current
Voltage, 1 V
11 12
13
14
11 12
13
14
+
+
-
-
V
mA
TC
Resistance, 2-wire
43
43
41 42
44
41 42
44
+
-
2-wire transmitter
Current
41 42
43
44
41 42
43
44
+
-
+
-
Tx
Voltage, 10 V
Relays
11 12
13
14
21 22
23
24
R1
R2
-
+
V
15