8021092 0717
--------------------------------------------------------------
- -------------------------------------------------------------
9260263 0717
WEO26 A00
8389000
4084971
9260095 ZNY8 (1.1.0)
Australia
Österreich
Phone +61 3 9457 0600
Phone +43 (0)22 36 62 28 8-0
Belgium/Luxembourg
Norge
Phone +32 (0)2 466 55 66
Phone +47 67 81 50 00
Brasil
Polska
Phone +55 11 3215-4900
Phone +48 22 837 40 50
Canada
România
Phone +1 905 771 14 44
Phone +40 356 171 120
Česká republika
Russia
Phone +420 2 57 91 18 50
Phone +7-495-775-05-30
China
Schweiz
Phone +86 4000 121 000
Phone +41 41 619 29 39
+852-2153 6300
Singapore
Danmark
Phone +65 6744 3732
Phone +45 45 82 64 00
Slovenija
Deutschland
Phone +386 (0)1-47 69 990
Phone +49 211 5301-301
South Africa
España
Phone +27 11 472 3733
Phone +34 93 480 31 00
South Korea
France
Phone +82 2 786 6321/4
Phone +33 1 64 62 35 00
Suomi
Great Britain
Phone +358-9-25 15 800
Phone +44 (0)1727 831121
Sverige
India
Phone +46 10 110 10 00
Phone +91–22–4033 8333
Taiwan
Israel
Phone +886-2-2375-6288
Phone +972-4-6801000
Türkiye
Italia
Phone +90 (216) 528 50 00
Phone +39 02 27 43 41
United Arab Emirates
Japan
Phone +971 (0) 4 8865 878
Phone +81 (0)3 5309 2112
USA/México
Magyarország
Phone +1(952) 941-6780
Phone +36 1 371 2680
Nederland
Phone +31 (0)30 229 25 44
SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch
Please find detailed addresses and additional representatives and agencies in
all major industrial nations at www.sick.com
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
More representatives and agencies at www.sick.com ∙ Subject to change
without notice ∙ The specified product features and technical data do not
represent any guarantee.
Weitere Niederlassungen finden Sie unter www.sick.com ∙ Irrtümer
und Änderungen vorbehalten ∙ Angegebene Produkteigenschaften und
technische Daten stellen keine Garantieerklärung dar.
Plus de représentations et d'agences à l'adresse www.sick.com ∙ Sujet à
modification sans préavis ∙ Les caractéristiques de produit et techniques
indiquées ne constituent pas de déclaration de garantie.
Para mais representantes e agências, consulte www.sick.com ∙ Alterações
poderão ser feitas sem prévio aviso ∙ As características do produto e os
dados técnicos apresentados não constituem declaração de garantia.
Flere repræsentanter og agenturer på www.sick.com ∙ Med forbehold for
ændringer og fejl ∙ De anførte produktegenskaber og tekniske data udgør
ikke nogen garantierklæring.
Altri rappresentanti ed agenzie si trovano su www.sick.com ∙ Contenuti
soggetti a modifiche senza preavviso ∙ Le caratteristiche del prodotto e i dati
tecnici non rappresentano una dichiarazione di garanzia.
Meer vestigingen en vertegenwoordigingen vindt u op www.sick.com ∙
Wijzigingen en correcties voorbehouden ∙ Aangegeven producteigenschap-
pen en technische gegevens vormen geen garantieverklaring.
Más representantes y agencias en www.sick.com ∙ Sujeto a cambio sin
previo aviso ∙ Las características y los datos técnicos especificados no
constituyen ninguna declaración de garantía.
欲了解更多代表机构和代理商信息,请登录 www.sick.com ∙
如有更改, 不另行通知 ∙ 对所给出的产品特性和技术参数
的正确性不予保证。.
Please note the validity of the additional operating
instructions for automation functions
Page 2 of 4
SICK device specific
Index
Name
dec
(hex)
13
Profile characteristic
(0x0D)
14
PDInput descriptor
(0x0E)
15
PDOutput descriptor
(0x0F)
58
Teach-in channel
(0x3A)
59
Teach-in state
(0x3B)
1
Teach flags
(0x01)
2
Teach state
(0x02)
60
Qint.1 SP1 / SP2
(0x3C)
1
SP1 upper threshold (switch-on)
(0x01)
2
SP2 lower threshold (switch-off)
(0x02)
61
Qint.1 configuration
(0x3D)
1
Switchpoint logic
(0x01)
2
Switchpoint mode
(0x02)
3
Switchpoint hysteresis
(0x03)
62
Qint.2 SP1 / SP2
(0x3E)
1
SP1 upper threshold (switch-on)
(0x01)
2
SP2 lower threshold (switch-off)
(0x02)
63
Qint.2 configuration
(0x3F)
1
Switchpoint logic
(0x01)
2
Switchpoint mode
(0x02)
3
Switchpoint hysteresis
(0x03)
64
Device / function name
(0x40)
114
Quality of teach
(0x72)
121
Pin 2 configuration
(0x79)
175
Quality of run
(0xAF)
176
Quality of run alarm threshold
(0xB0)
177
Quality of alignment
(0xB1)
204
Find me
(0xCC)
205
SICK profile version
(0xCD)
1
ro = read only, wo = write only, rw = read/write
2
COM values specify the bitrate (see IO-Link specification): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)
3
Subindex access not supported
ENGLISH
Format
Length
Access
1
Default
(Offset)
Value
3
Array
10 Byte
ro
Array
3
6 Byte
ro
3
Array
3 Byte
ro
UInt
8 Bit
rw
0
Record
3
1 Byte
ro
Bit (4)
1 Bit
ro
Bit (0)
4 Bit
ro
3
Record
2 Byte
rw
Bit (8)
8 Bit
rw
50
Bit (0)
8 Bit
rw
45
3
Record
4 Byte
rw
Bit (24)
8 Bit
rw
128
Bit (16)
8 Bit
rw
128
Bit (0)
16 Bit
rw
0
3
Record
2 Byte
rw
Bit (8)
8 Bit
rw
50
Bit (0)
8 Bit
rw
45
3
Record
4 Byte
rw
Bit (24)
8 Bit
rw
128
Bit (16)
8 Bit
rw
128
Bit (0)
16 Bit
rw
0
String
32 Byte
rw
*******
UInt
8 Bit
ro
UInt
8 Bit
rw
UInt
8 Bit
ro
UInt
8 Bit
rw
50
UInt
8 Bit
ro
UInt
8 Bit
rw
0
String
4 Byte
ro
Value / Range
Remark [Unit]
Unsigned Integer16 [5]
Octet String [2]
Octet String [1]
0...2 = Default BDC
false = Teachpoint 1 not taught
true = Teachpoint 1 successfully taught
0 = IDLE
1 = SP1 SUCCESS
5 = BUSY
50
[%]
45
[%]
128 = Vendor specific
128 = Vendor specific
0 = Autodefined hysteresis
50
45
128 = Vendor specific
128 = Vendor specific
0 = Autodefined hysteresis
0...100
[%]
0 = Deactivated / no function
1 = External input
17 = Teach-in
32 = Detection output Q/
33 = Quality of run alarm output
34 = Switching signal QL2
35 = Detection output Qint.1
39 = Switching signal QL1
0...255
[%]
0...90
[%]
0...100
[%]
0 = Find me deactivated