Fuse Protection
Sample Rate
Display
Over Range Indication
Low Battery Indication
Polarity Indication
Data Hold
Backlight
Auto Power-Off
Power Supply
Dimensions
Weight
Accessories
Voltage
Function
DC mV mV
DC V V
AC V
V~
1, 2
Frequency Range: 40Hz~500Hz
1
Response: avg, calibrated in RMS of sine wave
2
Manual range only
3
Overload protection: 1,000VDC or 1,000VAC RMS
Input impedance (nominal): > 10M < 100pF; AC voltage: > 5M < 100pF
Common mode rejection ratio: DC voltage: > 100dB @ DC; 50 or 60Hz; AC voltage: > 60dB @ DC, 50 or 60Hz
Normal mode rejection ratio: DC voltage: > 45dB @ 50 or 60Hz
Frequency
Function
Frequency Hz
(10Hz~100kHz)
Overload Protection: 1,000VDC or 1,000VAC RMS
DVM1100
µA and mA, F500mA / 250V, 5 x 20mm
A, F10A / 600V, 6.3 x 32mm
3x/sec for digital data
3
digits LCD with automatic indication of functions and symbols
¾
yes ("OL")
yes ( )
"-" displayed automatically
yes
white LEDs
yes
9V battery
180 x 85 x 45mm
± 360g (with battery)
manual, test leads, 9V battery, K-type thermocouple
Range
400mV
4V
40V
400V
1000V
400mV
3
4V
40V
400V
700V
Range
50.00Hz
500.0Hz
5.000Hz
50kHz
100kHz
- 10 -
Resolution
0.1mV
1mV
10mV
100mV
1V
0.1mV
1mV
10mV
100mV
1V
Resolution
0.01Hz
0.1Hz
0.001kHz
0.01kHz
0.1kHz
Accuracy
± 1.0% + 10 digits
± 0.5% + 3 digits
± 3.0% + 3 digits
± 1.0% + 3 digits
Accuracy
± 0.1% + 3 digits
VELLEMAN