MARLIN 1000, MARLIN 500
hydro fireplaces
(1) AIR ENTRY IN THE COATING: it is obligatory to always ensure a
minimum ventilation inlet and outlet in the coating through a grid at the
bottom and a grid above (decompression) of at least 450 cm2 each.
They can be done frontally, laterally or even later, provided that the
circle of air entering and leaving is always inside the house (and not
outside).
(2) INSPECTION DOOR: to load the
pellets into the tank, periodic maintenance
as well as annual cleaning of the chimney
flue, spare parts, it is mandatory to leave
the electronic components on the side (as
standard to right, looking at the chimney
from the front) a sufficient inspection door
to access all the components of at least
50x140 cm in height.
(3) HYDRAULIC KIT: MARLIN MH32 fireplaces can be supplied with
the hydraulic kit only for radiators (AC) or the hydraulic kit for radiators
and sanitary equipment (only the MARLIN 1000 MH32 ACS model).
On the right side of the chimney, we find the hydraulic and electrical
components:
CONSULT THE PRODUCT DATA SHEET to check the
components included and the fittings to be used.
Turbolators levers, electronic, smoke extractor, hydraulic kit and
pellet charger are mounted as standard (looking at the front fireplace)
on the right and can not be moved to the left (except the pellet load).
If you want to have all these components on the left you
have to buy the model dedicated to this purpose.
The hydraulic fireplaces do not have a hot air fan mounted on the
machine.
L'ARTISTICO SRL | EN
All manuals and user guides at all-guides.com
33
In hydro fireplaces it is mandatory to leave a
sufficient space above (at least 70 cm) for the eventual
maintenance, removal and repair of the turbulators (it is
therefore forbidden to recess them under a niche whose
upper part is not removable).
Heater and sanitary model
1 - Cold water return from the
plant
2 - Hot water supply
3 - Cold sanitary return
4 - Hot water supply to the plant
WARNING:
VERY
CHARGING THE WATER SYSTEM, ALL HYDRAULIC
MACHINING CONNECTIONS MUST BE VERIFIED AND
SEALED
BY
THE
INSTALLER
GUARANTE THE SEAT STEEL. We do not accept any
responsibility for water leakage from the fittings.
SUPERIOR DEFLECTORS
The hydraulic model does not have a higher smoke deflector placed in
the upper part of the combustion chamber.
Model heaters
1 - Cold water return from the plant
2 - Hot water supply to the plant
IMPORTANT:
BEFORE
TECHNICIAN
Cod. 40115 | Rev. 19 | 05/2021
TO