I. INSTALLATION
• Warning: this device must be installed only in volume 2 or outside volume of a
bathroom in accordance with the requirements of the French electrical installation
standard NF C 15-100.
• Note: The diagram below is given as an example only.
• INDOOR USE ONLY.
• A means of disconnection from the supply network having a contact opening
distance of all poles must be provided in the fixed trunking in accordance with the
installation rules.
• Attention: It is essential to cut off the current beforehand and connect the two
conductors of the H05VV-F 3x1.0mm² power supply cable to a connection box,
respecting the polarities below:
- Phase: Brown
- Neutral: Blue
• The minimum dimensions must be respected.
- Minimum height 80 cm.
- Distance between the side and a corner of the wall: min. 150 mm.
• If in doubt, seek advice from an experienced electrician before carrying out the
installation yourself to avoid a hazard.
• Grounding is prohibited.
- The installation must be equipped with an omnipolar cut-off device with a contact
opening distance of at least 3 mm.
- If the power cable is damaged, it must be replaced by the manufacturer, its after-
sales service or a similarly qualified person in order to avoid a hazard.
- In humid rooms such as bathrooms and kitchens, the connection box must be
installed at least 100 cm from the floor.
FIX THE RADIATOR TO THE WALL:
• ATTENTION: Once the radiator is installed, make sure that your installation is
stable and durable.
• The installation must be carried out according to the rules and in accordance with
the standards in force in the country of installation (NFC 15100 for France).
• Respect the minimum distances from obstacles for the location of the appliance. At
least 15cm between the radiator and the wall or ceiling and 60cm from the floor.
• Do not install the device:
- In a draft likely to disturb its regulation (under Centralized Mechanical Ventilation,
etc.).
- Under a fixed power socket.
- In volume 1 of the bathrooms.
- In volume 2 if the manipulation of the controls is possible by a person using the
shower or the bathtub.
The symbol of the crossed-out bin indicates that the product
must be sorted. It should be recycled in accordance with local
environmental waste regulations. By sorting products bearing
this pictogram, you are helping to reduce the volume of
incinerated or buried waste, and to reduce any negative impact
on human health and the environment.