Grand Canyon Gas Logs 3 BURNER Installation Et Manuel D'utilisation page 5

Publicité

3515 E Atlanta Ave,
Phoenix, AZ 85040
MODEL: 2-Burner:
MODEL: Gas:
2-Burner - BTU RATING 18" — 52k - NG 49k - LP
3-Burner - BTU RATING 18" — 46k - NG 41k - LP
NG Models
Altitude
Input
Reduced Input
P4
Manifold Pressure: 3.5" w.c. (NG)
Minimum Supply Pressure: 4.5" w.c. (NG)
Maximum Supply Pressure: 7"* w.c. (NG)
Pression au Collecteur: .87wPA d'une colonne d'eau (GN)
Pression d'Alimentation Min.: 1.25wPA d'une colonne d'eau (GN)
Pression d'Alimentation Max.: 10.5wPA ** d'une colonne d'eau (GN) **
Maximum inlet pressure not to exceed 13".
Minimum clearance to combustible materials: Top, sides & back: per
standoff spacers for framing and finishing materials. For non-combustible
framing and finishing materials, see installation manual.
APPAREIL DÉCORATIF À GAZ VENTILÉ: PAS UNE SOURCE DE CHALEUR; NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
CET APPAREIL A BESOIN D'AIR FRAIS POUR UN FONCTIONNEMENT SÉCURISÉ ET DOIT ÊTRE INSTALLÉ POUR IL Y A DES
This is a copy of the label that accompanies this gas burner. We have printed a copy of the contents here for your review. the safety label is
L'installation, y compris les dispositions pour la combustion, l'air de ventilation et l'ouverture de ventilation permanente minimale requise, doit
AVERTISSEMENT: Cet appareil à gaz ne doit pas être raccordé à un combustibl de cheminée desservant un appareil à combustible solide.
MANUEL D'INSTALLATION ET D'UTILISATION À 2 BRÛLEURS / 3 BRÛLEURS
ÉTIQUETTE DE SÉRIE
DO NOT REMOVE THIS LABEL
See installation & operating instructions for this model.
Contact local building officials about restrictions and
installation specifications in your area.
DATE
OF MFG.
 18
 24
3-Burner:
 18
 24
Valve:
 NG
 LP
36" — 81k - NG 83K - LP
36" — 111k - NG 106K - LP
GAS TYPE: NATURALGAS / LIQUID PROPANE
VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OF HEAT; NOT FOR USE WITH SOLID FUEL.
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED
SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
DISPOSITIONS POUR UN AIR DE COMBUSTION ET DE VENTILATION ADÉQUAT.
located near the rear of the burner. Please have your serieal # handy when calling in for warranty or other reasons.
The installation, including provisions for combustion, ventilation air, and required minimum permanent vent opening,
must conform with National Fuel Gas Code (ANSI Z223.1/NFPA 54) and applicable local building codes.
être conforme au National Fuel Gas Code (ANSI Z223.1 / NFPA 54) et aux codes du bâtiment locaux applicables.
WARNING: This gas appliance must not be connected to a chimney fuel servicing a solid fuel burning appliance.
WARNING: THIS FIREPLACE IS NOT INTENDED FOR BURNING SOLID FUELS.
AVERTISSEMENT: CE FOYER N'EST PAS DESTINÉ À BRÛLER DES COMBUSTIBLES SOLIDES.
SERIAL
#
 30
 36
 42
 30
 36
 42
 SPK
 MVQ
 MVKEI
24" — 64k - NG 64k - LP
30" — 76k - NG 79k - LP
42" — 86k - NG 87k - LP
24" — 74k - NG 64k - LP
30" — 102k - NG 91k - LP
42" — 120k - NG 121k - LP
MANIFOLD PRESSURE:
Pression au Collecteur: 2.40wPA d'une colonne d'eau (P)
Pression d'Alimentation Min.: 2.74wPA d'une colonne d'eau
(P) Pression d'Alimentation Max.: 3.49wPA * d'une colonne
d'eau (P) ** Pression d'alimentation maximale ne devait pas
dépasser 3.49wPA. Dégagements minimaux des matériaux
combustibles: Dessus, côtés et arrière: selon les espaceurs
de dégagements pour les matériaux d'ossature selon le
manuel du propriétaire pour les matériaux de finition
5
INSTRUCTIONS GÉNÉRALES
ANSI-Z21 60-2017
CSA 2.26-2
Decorative gas
Report # F23-191
appliances for
installation in solid-fuel
burning fireplaces.
LP Models
Élévation
Alimentation / Alimentation Réduite
P4
Manifold Pressure: 10" w.c. (LP)
Minimum Supply Pressure: 11" w.c. (LP)
Max. Supply Pressure: 14"* w.c. (LP)
GRANDCANYONGASLOGS.COM - 10_2023