Miele PDR 528 G Plan D'installation page 23

Masquer les pouces Voir aussi pour PDR 528 G:

Publicité

Les langues disponibles

Les langues disponibles

Possible voltage options
208/240 V   60 Hz   2 Ph
Power source
Total amps
Maximum fuse rating (time-delay fuse)
Minimum current
Exhaust air
Flow rate
Maximum permitted pressure loss
Maximum exhaust air temperature
Maximum evaporation rate
Exhaust gas connector on machine side
As relative humidity inside the exhaust ducting can be as high as 100%, suitable measures must be taken to prevent a backflow of con-
densate into the machine.
Supply air
Standard connection: air intake from installation site
Recommended free air intake cross-section into the room:
(equivalent to 3 times the exhaust air cross-section of a machine).
There must be sufficient air intake to the installation site to match the air outlet volume.
Alternative connection: air intake connection directly from outdoors
Connection sleeve on machine side (internal diameter)
Connection pipe provided on site (external diameter)
Removing the protective cover exposes live parts. For safety reasons, a pipe must be installed from the tumble dryer's central fresh air
intake (over a minimum length of 35 7/16" (900 mm)) and secured with 2 screws.
Gas connection
Appliance connection on machine side
Heater rating
Connection pressure natural gas
Jet pressure at minimum heating stage
Jet pressure at maximum heating stage
Equipotential bonding
Connection with male thread
Washers and nuts
Accessories for equipotential bonding are not supplied and need to be ordered separately.
en - Technical data
208/240 V
930 m³/h
176°F (80°C)
29.6 kg/h
6" (DN 150)
146 sq. in. (942 cm²)
6 5/16" (161 mm)
6 5/16" (160 mm)
62,780/113,620 BTU/hr
6.825–10.48 in.WC
(1,700–2,610 Pa)
1.00 in.WC (250 Pa)
3.41 in.WC
10 × 35 mm
60 Hz
2 Ph
7 A
15 A
8.8 A
290 Pa
½"
(850 Pa)
M10
23