Télécharger Imprimer la page

Ecler NXA Serie Mode D'emploi page 19

Publicité

Les langues disponibles

Les langues disponibles

DIGITAL
Analog Input headroom: +18 dBV = +21dBu
Digital Input attenuator: Stepless from – to +0dB
Compressor / Limiter:
Output peak voltage limiter:
Peak voltage upon model (auto settings) From 10Vpk to 70Vpk
High & Low pass Crossover filters Butterworth in 6/12/18/24dB/oct.
Parametric Eq. types (8 max. per output) - Bypass / On-Off all channels
Built In signal generator - Sine (20Hz to 20kHz)
Signal Polarity Invert Yes
Processing:
A/D & D/A 24 bit, 48kHz. 115dB AKM Codec
DSP 32/64 bits
Latency 2ms
Input Impedance: Balanced, 22k
Maximum Delay: 1s (343.4m) for each channel
Delay resolution: 20.8µs (6mm)
Threshold from -36dBV to +18dBV
Ratio 1:1 to :1 (limiter)
Attack time Auto or from 0.1ms to 500ms.
Release time Auto or from 1ms to 5s.
Bessel in 12/18/24dB/oct
Linkwitz-Riley in 12/24dB/oct.
- Param. Eq. 20Hz-20kHz; -60/+12dB; Q from =.3 to 200
- Low & High Shelf 6/12 dB/oct
- Low & High Pass 6/12 dB/oct.
- All-Pass 1/2 order
- Polarity(10/20Hz to 10/20kHz)
- White
- Pink
Signal Mute Yes
Connectivity: - Ethernet Base-Tx 10/100Mb, Auto X-Over, Cat5
- RS232 57600(fixed)-8-N-1-N