OPERATION OF THE EXTRACTOR UNIT
Set a number of minutes delay time
Use this function to switch off the extractor unit with a delay of a number of minutes.
The automatic extraction mode must be switched off.
1. Switch on the hob.
2. Touch the extraction key and set an extractor speed level.
3. Touch the timer display.
The timer symbol of the extractor unit lights up brightly.
4. Use the '+' or '-' key to set the desired delay time.
Countdown starts automatically.
The extractor unit switches off after the time that has been set.
Saturation of the grease filter
After 100 operating hours, the grease filter symbol is illuminated; it is necessary to perform
maintenance of the grease filter (see 'Maintenance/Cleaning the filters). The grease filter
saturation indication is always enabled.