3. Technical specification
3.1 Dimensional drawings
Type
Nominal performance
Heating capacity (m
-under favourable
-less favourable
-not favourable heating circumstances
according to 18893/TAB2 DIN standard
Flue gas values:
Flue gas stream:
Flue gas temperature:
Min. blast pressure at performance:
dust (relating to 13% O²)
CO (relating to 13% O²)
efficiency
All information provided by the exhaust gas values are based on the EN 13240 under stationary
laboratory conditions
3
)
fuel:
TYP11180
TYP11181
TYP11182
TYP11183
TYP11186
TYP11187
TYP11189
6 kW
116
69
47
firewood / BB7"
6,2 / 7,2 g/s
268 / 271°C
12 Pa
≤ 40 mg/m³
≤ 1250 mg/Nm
3
≥ 81 / ≥ 79 %
33
GB
TYP10180
TYP10181
TYP10182
TYP10183
TYP10186
TYP10187
TYP10189
8 kW
182
105
71
firewood / BB7"
7,9 / 8,6 g/s
295 / 316°C
12 Pa
≤ 40 mg/m³
≤ 1250 mg/Nm
3
≥ 80 / ≥ 78 %

Publicité