1.2 Installation
Fuels
Low smoke, trouble-free operation of the stove and a supply of heat at the nominal
level with a chimney draught of 12 Pa are only guaranteed when you use the fol-
lowing fuels and no others.
Only use natural, dry chopped firewood with a remaining humidity of max. 20%,
and lignite (brown coal) briquettes.
With the primary air damper, do you adjust the rated output.
There may be engaged in only the settings and fuel quantities are
given that correspond to your licensed or purchased device.
Adjustment:
Fuel
Warning up,
kindling
Nominal heating
Wood
performance
Nominal heating
Brown-coal
performance
Putting out of working
order
Filling quantities 6 kW
-Split billet: max. length: 33 cm, max. 2 billets per filling, appr. 1,4 kg
-Lignite briquette: max. 1,6 kg
Filling quantities 8 kW
-Split billet: max. length: 33 cm, max. 3 billets per filling, appr. 2,0 kg
-Lignite briquette: max. 2,2 kg
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with pre-
ventive chemicals, furthermore paper and cardboard. For kindling please use wood
scrapings or grill starter but never use liquid auxiliaries!
The first kindling
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
Types of fuels
Hard wood
Soft wood
Brown-coal
Setting of the pri-
mary air regulator
8 kW
IIII
II
III
I
Heating value appr.
kJ/kg
19.500
15.900
11.500
6 kW
IIII


I
Table 2
25
Setting of the
fuel selector
H
H
K
K
Burning
time
-
ca. 0,75 h
ca. 1 h
-