Indication on the product
1 green LED.
2 green LEDs.
3 green LEDs.
3 green LEDs and 1 yellow
LED.
3 green LEDs, 1 yellow
LED and 1 red LED.
All LEDs flash.
1 green LED flashes.
Accessories
Accessory
Drill stand DS 500
Slurry ring*
Sealing disc*
Rubber washer, part num-
ber 598 72 14-01
* Contact you local service agent for more information
Approved service center
To find your nearest Husqvarna Construction Products
approved service center, go to the web site
www.husqvarnacp.com.
20
Cause
The tool is connected to mains voltage and can
be used.
Power output is less than 50% of available out-
put power.
Power output is between 50% and 65% of avail-
able output power.
Power output is between 65% and 80% of avail-
able output power.
Maximum power output. Power output is more
than 80% of available output power.
There is a system overload.
™
Elgard
motor overload protection is started.
™
Elgard
motor overload protection has stopped
the motor.
™
Smartstart
is started.
Accessories
DM 370 [EU]
Securing by
Other secur-
vacuum pad:
ing: OK
OK
OK
OK
OK
Service
Possible solution
N/A
Decrease the load to prevent start of
the Elgard
tion.
Decrease the load to go back to cor-
rect operation.
Refer to
protection on page 13 .
Refer to
page 12 .
DM 400
Securing by
Other secur-
vacuum pad:
ing: OK
OK
OK
OK
OK
™
motor overload protec-
To reset the motor overload
™
To use Smartstart
on
DM 430
Securing by
Other secur-
vacuum pad:
ing: OK
OK
OK
OK
OK
1188 - 010 - 30.11.2022