12 Volt AdvancedNotification System
OPERATING INSTRUCTIONS & PARTS MANUAL
QUICK START INSTRUCTIONS
STEP 1 - VERIFY PACKAGE CONTENTS
Transformer (1)
Lid and Controller Assembly (1)
Battery box (1)
12 Volt DC back-up pump (1)
Switch with clamp (1)
Requires active telephone land line service
STEP 2 - DISCONNECT POWER
is out of sight, lock in the open
position and tag it to prevent
unexpected application of power.
Failure to do so COULD result in fatal
electric shock!
STEP 3 - INSTALL BACK-UP AND FLOAT SWITCH
STEP 4 - INSTALL BATTERY
Model RSM3300 – Operating Instructions and Parts Manual
Does not include:
12 Volt DC deep cycle
battery, phone jack,
phone line, pipe, and
necessary fittings.
If the power disconnect
Acceptable Batteries
WAYNE - WSB1275
WAYNE - WSB1240
or
12 Volt Deep Cycle Marine Battery
12 Volt SLA (Sealed Lead Acid)
12 Volt Deep Cycle Battery
12 Volt Wet Cell Battery
Size = min 40Ah
Ridge Tool Company
STEP 5 - CONNECT LID TO BATTERY
Black
STEP 6 - CONNECT WIRES
Float Switch
Security
Phone
STEP 7 - POSITION BATTERY AND CONTROLLER
Drain
Tile
STEP 8 - CONTROLLER SETUP
Startup Display
Select Language
English
Español
Français
Select the starting language and follow the on-screen
instructions to set up the controller. Upon completion of
controller setup, restore AC power and test the main pump as
described in the operation section of the manual.
RSM3300
Wear safety glasses when
connecting the battery
Red
Transformer
DC Pump
12
9
3
6
Minimum charge time
before usage is 24 hours
Home Display
12.1 V
100%
Last Auto Test: --/--/--
System Armed & Ready
MENU MUTE RESET
1